Table 14. POST beep codes
POST error messages
The following tables provide information about the POST error messages that can
appear during startup.
POST message
062
The server failed to boot on three consecutive attempts.
All caches are disabled. Repeatedly turning the server on and then off or resetting the
server might cause this problem.
Action:
If the problem persists, call for service. When the problem is corrected, be sure to enable
the caches.
101
An error occurred during the system board and microprocessor test.
102
Action:
106
114
An adapter read-only memory (ROM) error occurred.
Action:
If you cannot isolate and correct the problem, call for service.
Table 15. POST error messages
112
IBM® Netfinity® 4500R User's Reference
1-2-4
RAM refresh verification has failed.
1-3-1
First 64 Kb RAM test has failed.
1-3-2
First 64 Kb RAM parity test has failed.
3-3-1
A memory size mismatch has occurred.
3-3-3
No memory has been detected in the system.
Start the Configuration/Setup Utility program and verify that all settings
are correct. Use the Cache Control selection in the Advanced Setup menu
of the Configuration/Setup Utility program to enable the caches.
Call for service.
Remove the options. If you can start the server without the options
installed, reinstall each option one at a time and retest after each is
reinstalled. When an option fails, replace it.
Description
Reseat the
memory
modules or
install a
memory
module. If the
problem
persists, call for
service.