IBM Netfinity 4500R User Reference Manual page 141

Hide thumbs Also See for Netfinity 4500R:
Table of Contents

Advertisement

Code
Function
089
Microprocessor Failed
165
Service
processor
175
System thermal Failed
180
Status display
Table 17. Diagnostic error messages
Result
Test setup error: Application microprocessor not
installed or BIOS setup problem
VRM corresponding to Microprocessor in socket
xyz is defective
(where xyz identifies the microprocessor whose
VRM is causing the error message)
VRM corresponding to Microprocessor in socket
id xyz is not installed
(where xyz identifies the microprocessor whose
VRM is causing the error message)
Failed
Netfinity Advanced System Management
Processor on system board
Fan # n
(where n is the number of the failing fan)
The fan LED on the diagnostic LED
Note:
panel will be lit.
Temperature sensed on processor board is out of
range
Failed
Diagnostic LED panel
Operator information panel
LED on hot-swap SCSI backplane
LED on processor board
LED on system board
Text message
Action
1. Verify that the
Application
microprocessor is
installed and
seated correctly.
2. Check the system
error log for
related error
messages.
3. If your server does
not have the latest
level BIOS
installed, update
the BIOS.
4. If the problem
remains, replace
the application
microprocessor
and run the test
again.
If the problem persists,
call for service.
Replace the VRM.
If the problem
remains, call for
service.
Install a VRM.
If the problem persists,
call for service.
Call for service.
Replace the indicated
fan
If one of the fan LEDs
on the diagnostic LED
panel is on, replace the
indicated fan. If the
problem persists, call
for service.
Call for service.
Chapter 7. Solving problems
129