PCNTNW-NW-071 The matching virtual adapter could not be found.
Explanation: You tried to load another instance of the driver with a different I/O
address. This new adapter could not be found.
Action: Verify that you installed an IBM Netfinity 10/100 Fault Tolerant Adapter
and make sure that the adapter is seated correctly. If the adapter is seated correctly,
call for service.
PCNTNW-NW-072 A resource tag is unavailable.
Explanation: The driver tried to allocate some resources that were not available.
Action: Add more memory, or free some memory resources in the server. Then,
restart the server.
PCNTNW-NW-073 Unable to allocate memory
Explanation: The driver failed to allocate the memory needed for normal operation.
Action: Add more memory, or free some memory resources in the server. Then,
restart the server.
PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware interrupt. The
attempt was not successful.
Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is
enabled, go to "Starting the diagnostic programs" on page 124 to run the diagnostic
programs.
If you have an Ethernet adapter installed, make sure that the adapter does not share
an IRQ with any other device.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the Link
Support Layer (LSL).
Explanation: An error occurred while the driver was trying to register with the LSL.
Action: Check the version of the NetWare or IntraNetWare Operating System. Make
sure that this driver is correct for the version of NetWare or IntraNetWare that you
are using. Restart the server.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-086 The driver parameter block is too small.
Explanation: The driver parameter block is too small.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The driver media parameter block is too small.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-091 The hardware configuration conflicts.
Explanation: You tried to load a new frame type for the existing controller. The
hardware assumptions made in doing so are incorrect. This error can also occur if
you try to specify a mode (such as, redundancy) that conflicts with another specified
mode.
Action: Make sure that your hardware configuration matches the software settings.
Table 22. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet
controller