Troubleshooting
Device
CD-ROM drive
CD-ROM drive is not
recognized.
Diskette drive
Diskette drive in-use light
stays on, or the system
bypasses the diskette drive.
Expansion enclosure
problems
The SCSI expansion
enclosure used to work, but
does not work now.
General problems
Problems such as broken
cover locks or indicator
lights not working.
140
IBM® Netfinity® 4500R User's Reference
If you cannot find the problem in the troubleshooting charts, go to "Starting the
diagnostic programs" on page 124 to test the server. If you have run the diagnostic test
programs or if running the tests does not reveal the problem, call for service.
Look for the symptom in the left column of the chart. Instructions and probable
solutions to the problem are in the right column. If you have just added new software
or a new option and your server is not working, do the following before using the
troubleshooting charts:
Remove the software or device that you just added.
Run the diagnostic tests to determine if your server is running correctly.
Reinstall the new software or new device.
Verify that:
1. The primary IDE channel is enabled in the Configuration/Setup Utility
program.
2. All cables and jumpers are installed correctly.
3. The correct device driver is installed for the CD-ROM drive.
If the problem remains, call for service.
If there is a diskette in the drive, verify that:
1. The diskette drive is enabled in the Configuration/Setup Utility
program.
2. The diskette is good and not damaged. (Try another diskette if you have
one.)
3. The diskette contains the necessary files to start the server.
4. Your software program is OK.
If the diskette drive in-use light stays on, or the system continues to bypass
the diskette drive, call for service.
Verify that:
1. The cables for all external SCSI options are connected correctly.
2. The last option in each SCSI chain, or the end of the SCSI cable, is
terminated correctly.
3. Any external SCSI option is turned on. You must turn on an external
SCSI option before turning on the server.
For more information, see your SCSI and expansion enclosure
documentation.
Call for service.
Table 20. Troubleshooting charts
Suggested action