IBM Netfinity 4500R User Reference Manual page 139

Hide thumbs Also See for Netfinity 4500R:
Table of Contents

Advertisement

Code
Function
35
ServeRAID
075
Power supply
Table 17. Diagnostic error messages
Result
Aborted
Test setup error: No ServeRAID adapter found
on system board or PCI bus
Failed
Adapter in slot n; adapter/drive configuration
error
(where n is the slot number of the failing
adapter)
Adapter in slot n; internal error
(where n is the slot number of the failing
adapter)
Logical drive m on adapter in slot n
(where m is the number of the failing logical
drive and n is the slot number of the adapter)
On system board; internal error
On system board; adapter/drive configuration
error
Logical drive on system board adapter
Adapter in slot n; memory allocation error
(where n is the slot number of the failing
adapter)
On system board; memory allocation error
On system board; PCI configuration error
On system board; POST error
Adapter in slot n; POST error
(where n is the slot number of the failing
adapter)
Adapter in slot n; PCI configuration error
(where n is the slot number of the failing
adapter)
SCSI drive on adapter in slot n, SCSI ID m
(where n is the slot number of the adapter and m
is the SCSI ID of the drive)
Failed
Voltage sensed by the system is out of range
Text message
Action
Make sure the
ServeRAID adapter is
properly installed.
If the problem
remains, replace the
ServeRAID adapter.
If the problem persists,
call for service.
Run the ServeRAID
Configuration Utility.
If the problem
remains, replace the
ServeRAID adapter in
slot n.
If the problem persists,
call for service.
Run the ServeRAID
Configuration Utility.
If the problem persists,
call for service.
Call for service.
Replace the
ServeRAID adapter in
slot n. If the problem
persists, call for
service.
Check the cable and
power connections on
the drive. If the
problem persists, call
for service.
Call for service.
Chapter 7. Solving problems
127