IBM Netfinity 4500R User Reference Manual page 138

Hide thumbs Also See for Netfinity 4500R:
Table of Contents

Advertisement

Code
Function
020
PCI interface
030
SCSI interface
Table 17. Diagnostic error messages
126
IBM® Netfinity® 4500R User's Reference
Result
Failed
System board
Tab on PCI Hot Swap slot #n is bad
(where n is the number of the failing PCI slot)
Note:
For normal operation, the Power LED
for the hot-plug PCI slot will be on and
the Attention Led will be off.
Failed
SCSI adapter in slot n failed register/counter/
power test
(where n is the slot number of the failing
adapter)
SCSI controller on system board failed
register/counter/power test
Text message
Action
Call for service.
Make sure the tab and
latch on hot-plug PCI
slot n are closed
correctly.
If the problem persists,
call for service.
Refer to the
information provided
with the adapter for
instructions.
If the problem persists,
call for service.
Call for service.

Advertisement

Table of Contents
loading