OMR Error Messages
Message
Bad OMR marks
Spacing
No OMR marks
Bad OMR Code
length
Bad OMR Code
format
Expected 1st
Sheet of set
Not a new
Envelope
OMR: Parity Error
OMR: Sequence
Error
OMR: SF marks
Inconsistent
OMR: SF not in
Use
OMR: Set too
Large
OMR: End of
Batch
Ready to Run
Mode Change
Recheck Feeders
SV63138 Rev.A
Two marks that are closer together than half the
expected distance are read. Check scan marks on
material.
• No marks on paper.
• Scan sensor is not centered over scan marks.
• Paper not loaded correctly.
Code type on paper does not match the setup.
(Example: setup has OMR+ Sequence but paper
has OMR + Select Feed + Sequence.)
A re-timing scan mark is missing. Check material.
(Example: mark 6 missing from a 10 mark code.)
The BOC mark (position 4) was present when it was
not expected. First page of the set was expected.
The BOC mark (position 4) was absent when it was
expected. Pages other than the first page of the set
were expected.
The code doesn't have an even number of marks.
The sequence number is not sequential with the
previous page fed. Therefore, sheets are in the
wrong order or missing.
The Selective feed and Autobatch marks at
positions 7 to 9 are different from those on the
previous sheet of this set.
A selective feed mark is present at positions 7 to 8,
but the job setup does not include select feed.
The set contains too many sheets from the main
feeder.
• Inserter has stopped for "End of Batch."
• Allows the operator to manually sort envelopes.
Check sheet and insert feeder settings against the
job you are loading before exiting the setup mode.
OMR Scanning • 4