4 • OMR Scanning

OMR Troubleshooting

Error Recovery for OMR Jobs

If the inserter stops during an OMR job, and indicates one of the error
messages listed below, follow these steps.
1. Tap the Clear Deck button on the
control panel. Any envelope at the
insertion area will eject into the stacker.
2. The remaining pages of the current set
will feed/fold and eject into the stacker.
Manually insert into the envelope if
necessary.
3. The FIRST page of the NEXT set will
pre-feed into the feed rollers and stop.
Pull the sheet back to the normal feed
position .
4. Tap the Start button to resume
operation.

Error Recovery for Accumulation Jobs

If the inserter stops during an accumulation job, follow these steps.
1. Tap the Clear Deck button on the control panel.
2. The envelope at the insertion area ejects into the stacker. You must
manually remove the remaining pages of the set from the feeder.
3. Fold/insert the remaining pages into the envelope.
4. Tap the Start button to resume operation once you've determined
the cause of the stoppage.

Error Recovery for Empty Feeders

If any feeder runs out of material the inserter will stop, and the following
instructions scroll across the display.
1. Re-fill the empty tray.
2. Tap START to continue OR tap STOP and Clear Deck.
3. Reload the feeders and proceed as required.