CRS-300 1:10 Redundancy Switch
Front Panel Operation

7.4.4 CONFIG: REMOTE

SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)
Select LOCAL or REMOTE using the ◄ ► arrow keys, then press
CONFIG: REMOTE
If LOCAL is selected, remote control will be disabled, though remote monitoring is always
possible.
CONFIG: REMOTE
If REMOTE is selected:
REMOTE CONTROL: BAUDRATE
INTERFACE
Select BAUDRATE or INTERFACE, using the ◄ ► arrow keys, then press
CONFIG: REMOTE
If BAUDRATE is selected:
EDIT SWITCH BAUDRATE:
19200 BAUD
The User may select the baud rate of the remote control bus, connected locally to the M&C
computer. Change the value by using the ▲ ▼ arrow keys. Values of 300, 1200, 2400, 4800,
9600 and 19200 baud are possible.
Once baudrate has been set, the User should pres ENT.
Note: This setting does not affect the internal communications between the Switch and the modems.
CONFIG: REMOTE
If INTERFACE is selected:
ELECT. INTERFACE:
RS485-2W
Select RS232, RS485-2W (2-wire), or RS485-4W (4-wire) using the ◄ ► arrow keys, then press
[ENT]
. The User will be further prompted to enter the bus address.
In this example, RS-232 mode is used and the bus address is fixed at 0:
IN RS232 MODE THE BUS
ADDRESS IS FIXED AT 0000
If in RS-485, the address may be selected. The valid addresses are 1000, 3000, 5000 and 7000
only, as explained in
LOCAL
REMOTE
(PRESS ENTER)
REMOTE
BAUDRATE
(PRESS ENT)
REMOTE
INTERFACE
RS232
RS485-4W (ENT)
Appendix C. REMOTE CONTROL
7–11
.
[ENT]
[ENT]
in this manual.