Comtech EF Data CRS-300 Installation And Operation Manual page 263

1:10 redundancy switch
Hide thumbs Also See for CRS-300:
Table of Contents

Advertisement

CRS-300 1:10 Redundancy Switch
Remote Control
Arguments for
Command
Command or
Parameter Type
(Code and
Response to
qualifier)
Serial Number
N/A
9 bytes, numerical
Software
N/A
4 bytes, numerical
Revision
Time
TIM=
6 bytes, numerical
Description of Arguments
(Note that all arguments are ASCII numerical codes,
that is, ASCII codes between 48 and 57)
Query
Query only.
Unit returns its 9-digit serial number.
Example: SNO=176512523
Query only.
Unit returns the value of internal software revision installed
in the unit, in the form x.xx
Example: SWR=1.03 (Ver 1.03)
Command or Query.
The time from midnight, in the form hhmmss, where
hh = hours, between 00 and 23,
mm = minutes, between 00 and 59, and
ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and
59 seconds from midnight.
Response to Command
(Target-to-Controller)
N/A
N/A
TIM= (message OK)
TIM? (received OK, but
invalid arguments)
TIM# (message OK, but
only permitted in Remote
mode)
C–13
Revision 16
MN/CRS300.IOM
Query
Response to query
(Code and
(Target-to-Controller)
qualifier)
SNO?
SNO=xxxxxxxxx
(see Description of
Arguments)
SWR?
SWR=x.xx
(see Description of
Arguments)
TIM?
TIM=hhmmss
(see Description of
Arguments)

Advertisement

Table of Contents
loading

Table of Contents