CRS-311 1:1 Redundancy Switch
Front Panel Operation
5.2.2.5
(CONFIG:) REMOTE
SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)
Use the ◄►arrow keys to select LOCAL or REMOTE, and then press ENTER.
5.2.2.5.1
(CONFIG: REMOTE)
Selecting LOCAL disables remote control, although remote monitoring is always possible.
5.2.2.5.2
(CONFIG: REMOTE)
REMOTE CONTROL: BAUDRATE
INTERFACE
Use the ◄►arrow keys to select BAUDRATE, INTERFACE, or FORMAT, and then press ENTER.
5.2.2.5.2.1 (CONFIG: REMOTE
EDIT SWITCH BAUDRATE:
9600 BAUD
Use this submenu to select the baud rate of the remote control bus connected locally to the M&C
computer. Use the ▲▼arrow keys to select a baud rate of 300, 1200, 2400, 4800, 9600, or
19200, and then press ENTER.
This setting does not affect the internal communications between the Switch and
the modems. For the SLM‐5650, this is fixed at RS‐232, 9600 baud, 8‐N‐1.
5.2.2.5.2.2
(CONFIG: REMOTE
ELECT. INTERFACE:
RS485-2W
Use the ◄►arrow keys to select the remote interface as RS‐232, RS485‐2W (2‐wire), or RS485‐
4W (4‐wire). Press ENTER to enter the bus address:
IN RS232 MODE THE BUS
ADDRESS IS FIXED AT 0000
In the previous screen, RS‐232 mode is selected and the bus address is fixed at 0.
FORMAT
(ENT)
REMOTE) BAUDRATE
(PRESS ENT)
RS232
RS485-4W (ENT)
LOCAL
REMOTE
REMOTE) INTERFACE
5–10
Revision 7
MN/CRS311.IOM