Ethernet Traffic Data Connections; Ethernet Bridge Mode Via The Optional Gbe Interface; Ethernet Bridge Mode Via The Optional Np Interface - Comtech EF Data CRS-300 Installation And Operation Manual

1:10 redundancy switch
Hide thumbs Also See for CRS-300:
Table of Contents

Advertisement

CRS-300 1:10 Redundancy Switch
Cables and Connections
HSSI (HD-50F) connector labeled "J2" on the RMI or "J3" on the TMI(s), to
HSSI (HD-50F) connector labeled "J7 HSSI" on the SLM-5650/5650A.
If EIA-530/-232 is the traffic data type, connect and secure the Control/Data Cable CA/WR0066
(used for data purposes) between the CRS-300 and each SLM-5650/5650A as follows:
DB-25M connector labeled "P2" on the RMI, or "P1" on the TMI(s), to
DB-25F connector labeled "J6 EIA530" on the SLM-5650/5650A.
Referring to Figure 4-33:
If Balanced G.703 is the traffic data type , connect and secure the CA/WR9038-1 cable between
the CRS-300 and each SLM-5650/5650A as follows:
DB-15M connector labeled "P1" on the RMI or TMI(s), to
DB-15F connector labeled "J1 Bal Data" on the SLM-5650/5650A.
If Unbalanced G.703 is the traffic data type, connect and secure the pair of BNC PL/0813-8
cables between the CRS-300 and each SLM-5650/5650A as follows:
BNC connectors labeled "J4 Tx" on the RMI, or "J3 Tx" on the TMI(s), to BNC
connectors labeled "J3 Rx" on the SLM-5650/5650A, and
BNC connectors labeled "J3 Rx" on the RMI, or "J5 Rx" on the TMI(s), to BNC
connectors labeled "J2 Tx" on the SLM-5650/5650A.

4.10.3.1 Ethernet Traffic Data Connections

Due to limitations of its backplane, the CRS-300 can support Single-port Ethernet Bridge
Mode only.
4.10.3.1.1

Ethernet Bridge Mode via the Optional GbE Interface

When the SLM-5650/5650A modems are equipped with the optional single-port 10/100/1000
Base-T (GbE) Interface card, only Single-port Ethernet Bridge Mode is possible. As shown in
Figure 4-32 , connect and secure all Cat5 Data Cables PP/CAT5FF3FTGY as follows:
RJ-45 connector labeled "J5" on the RMI or TMI, to
RJ-45 connector labeled "J1" on the optional GbE Interface card.
4.10.3.1.2

Ethernet Bridge Mode via the Optional NP Interface

When the SLM-5650/5650A modems are equipped with the optional multi-port Network
Processor (NP) Interface card, only Single-port Ethernet Bridge Mode is possible. As shown in
Figure 4-34 , connect and secure all Cat5 Data Cables PP/CAT5FF3FTGY as follows:
RJ-45 connector labeled "Port 1" on the RMI or TMI, to
RJ-45 connector labeled "Port 1" on the optional Network Processor (NP) Interface card.
IMPORTANT
Do not connect to Port 2 through Port 4 on the RMI, TMI, or optional
Network Processor (NP) Interface when operating in Single-port
Ethernet Bridge Mode.
4–73