5-9. Diagnostic LED's On Customer Interface Board PC14

LED
Status
On
1
1
Off
On
2
2
Off
On
3
3
Off
On
4
4
Off
5
On
Off
6
On
Off
7
On
Off
On
8
8
Off
On
9
9
Off
On
10
10
Off
On
11
11
Off
12
On
Off
13
On
Off
On
14
14
Off
On
15
15
Off
On
16
16
Off
On
17
17
Off
On
18
18
Off
On
19
19
Off
20
On
Off
On
21
Off
22
On
Off
OM-196 188 Page 32
Indicates –15 volts dc RA supply is present on customer interface board PC14.
Indicates –15 volts dc RA supply is not present on customer interface board PC14.
Indicates +15 volts dc RA supply is present on customer interface board PC14.
Indicates +15 volts dc RA supply is not present on customer interface board PC14.
Input signal On from robot for no Emergency Stop.
Input signal Off from robot for Emergency Stop.
Indicates +24 volts dc RD supply is present on customer interface board PC14.
Indicates +24 volts dc RD supply is not present on customer interface board PC14.
Input signal On from robot for shielding gas.
Input signal Off from robot for no shielding gas.
Input signal On from robot to energize contactor.
Input signal Off from robot to not energize contactor.
Input signal On from robot for jog retract.
Input signal Off from robot for no jog retract.
Input signal On from robot for jog advance.
Input signal Off from robot for no jog advance.
Indicates automatic configuration Bit D is set.
Indicates automatic configuration Bit D is not set.
Input signal On for RPS-C.
Input signal Off for RPS-C.
Input signal On for RPS-B.
Input signal Off for RPS-B.
Indicates remote program A selected.
Indicates remote program A not selected.
Input signal On from peripheral for touch sensor.
Input signal Off from peripheral for no touch sensor.
Indicates automatic configuration Bit B is set.
Indicates automatic configuration Bit B is not set.
Indicates automatic configuration Bit A is set.
Indicates automatic configuration Bit A is not set.
Indicates automatic configuration Bit C is set.
Indicates automatic configuration Bit C is not set.
Input signal On from relay CR4 for wire stuck in weld joint.
Input signal Off from relay CR4 for wire not stuck in weld joint.
Input signal On from relay CR6 for flow (shielding gas or coolant) present.
Input signal Off from relay CR6 for flow (shielding gas or coolant) not present.
Input signal On from relay CR5 for arc detect.
Input signal Off from relay CR5 for no arc detect.
Input signal On from relay CR2.
Input signal Off from relay CR2.
Input signal On from relay CR1 for welding power source ready and no detected errors present.
Input signal Off from relay CR1 for welding power source not ready, detected errors are present, or unit
is in Setup or Control mode.
Input signal On from peripheral for flow switch.
Input signal Off from peripheral for no flow switch.
Diagnosis