3-10. Peripheral Receptacle Functions

A
A
K
K
J
J
B
M
M
C
C
L
H
D
E F
E F
*Circuit common is same electrical reference point.
**Speed of Jog + and Jog – is at setup value for Jog IPM parameter.
{ Socket M can be changed to 0 volts dc (common) for part touched output signal (see Section 3-12).
Note: A customer supplied matching amphenol plug [Miller Part No. 194 847 (Amphenol Part No. MS3106A20-33P and strain relief clamp
AN3057-12)] is required to use peripheral receptacle.
Function
Programmable
Output Relay Con-
Output Relay Con-
tacts
Purge
Coolant Flow
Switch Input
Signal
Signal
Jog +
Jog –
802 748
Touch Sensor ON
Touch Sensor ON
And Output Signal
And Output Signal
Socket
Socket Information
A
Contact closure to B dependent upon state of
programmed output (see Section 14-5). The closure
between A and B can carry a maximum of 0.6
amps at 125 VAC; or a maximum of 0.6 amps at
110 VDC.
B
Contact closure to A dependent upon state of
programmed output (see Section 14-5). See socket
A information for current carrying capacity of
closure.
C*
Circuit common.
D
Contact closure to C completes 24 volts dc
solenoid circuit to purge shielding gas line.
E
Contact closure to F indicates coolant flow switch is
closed and recirculating coolant system is
operational.
F*
Circuit common.
H**
Contact closure to circuit common advances
welding wire at wire drive assembly.
J**
Contact closure to circuit common retracts welding
wire at wire drive assembly.
K
Contact closure to L energizes Touch Sensor
circuitry.
L*
Circuit common.
M{
Part touched is selectable for either 0 volts dc
(common) or +24 volts dc (see Section 3-12).
Part touched +24 volts dc output signal referenced
to circuit common is factory default setting.
OM-196 188 Page 17