Selecting Arc Start Method; Resetting Arc Time - Miller Electric Welder Owner's Manual

Operating instructions and programming instructions
Table of Contents

Advertisement

14-7. Selecting Arc Start Method

NOTE
Access
Setup
Display
Press Mode
Select
Aux Output
Voltage
> ArcStart
Arc Time
2

14-8. Resetting Arc Time

Access
Setup
Display
Press Mode
Select
Voltage
ArcStart
> Arc Time
Wirefeed
Arc Start selection is not used when welding in non-pulsed MIG.
Do not use the Hot Start setting for .035 in (9 mm) or smaller wire.
Pulse
ArcStart
> Standard
1
ArcStart
Increase
Type
> Hot Start
1
0 .00 Hrs
Increase
0 Cycl
> No Reset
ArcStart
Type
> SoftStart
3
0.00 Hrs
0 Cycl
> Reset
Press
1
Standard Start
Welding operation is performed at
set values for welding parameters.
2
Hot Start
Use the Hot Start mode for pulse
welding when high initial weld
current is necessary to start large
diameter welding wires. When in
Hot Start, welding power source
starts the arc in the CV mode and
switches to CC once the arc is
started.
3
Soft Start
Use the Soft Start mode for .035 in
(9 mm) or smaller wire. Low wire
feed speeds may also require the
Soft Start mode. Arc start is at 75%
of maximum amperage for pulse
welding and once an arc is
established, welding is performed
at set parameter values.
1
Arc Time Display
The unit accumulates arc hours up
to 9999.99 hours or 999999 weld
cycles before rolling over to zero
(0). The arc timer can be reset using
this display or by performing a total
reset (see Section 14-12).
OM-196 188 Page 111

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auto invision ii

Table of Contents