Setting Teach Point Parameters For Pulse Welding Program - Miller Electric Welder Owner's Manual

Operating instructions and programming instructions
Table of Contents

Advertisement

10-4. Setting Teach Point Parameters For Pulse Welding Program

> Process
Sequence
SharpArc
Card
31.2 Vpk
343 Apk
> 92 Abk
160 PPS
Parameter
Select
31.2 Vpk
343 Apk
92 Abk
> 160 PPS
4
When the Process Teach mode is On, and
one of the following pulse parameters is se-
lected: Apk, Abk, PPS, PWms, or Vpk, the
pulse panel displays the selected pulse pa-
rameter instead of Trim (arc length). When
the pulse parameter is selected, the value
can be changed with the pulse panel controls
as follows:
1
Vpk Display
Teach On
> 450 IPM
28.1 Vpk
340 Apk
Parameter
Increase/
Decrease
31.2 Vpk
343 Apk
> 70 Abk
160 PPS
3
Increase/
Decrease
31.2 Vpk
343 Apk
92 Abk
> 280 PPS
6
Prg 1
C
Pulse
035" Steel
Argon – Oxy
2
Apk Display
3
Abk Display
4
PPS Display
5
PWms Display
When values have been set for a teach point,
strike and maintain an arc for five seconds.
Repeat procedure at each teach point until
custom program is complete (see Section
10-2).
Increase/
Decrease
Teach On
450 IPM
> 28.1 Vpk
340 Apk
Select
1
450 IPM
31.2 Vpk
> 343 Apk
70 Abk
Parameter
Select
343 Apk
92 Abk
280 PPS
> 1.9 PWms
Parameter
Select
5
Pulse
035" Steel
Argon – Oxy
> Teach Off
Parameter
Select
Turn Teach mode Off.
6
The letter C will appear in the upper right
corner of all customized programs.
Customized programs can be reverted back
to factory-set values through memory reset
(see Section 14-12).
Teach On
450 IPM
Or
> 31.2 Vpk
340 Apk
Parameter
Select
Increase/
Decrease
450 IPM
31.2 Vpk
> 340 Apk
70 Abk
Wait for 5
seconds
343 Apk
92 Abk
280 PPS
> 3.6 PWms
Increase/
Parameter
Decrease
Increase/
Decrease
> Teach On
450 IPM
31.2 Vpk
343 Apk
Custom Pulse Screen
OM-196 188 Page 93
2
Select

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auto invision ii

Table of Contents