Setting Crater Sequence Display; Setting Retract Sequence Display - Miller Electric Welder Owner's Manual

Operating instructions and programming instructions
Table of Contents

Advertisement

11-6. Setting Crater Sequence Display

> Cratr
0.02 Sec
24.0 Volt
90 IPM
Parameter
Select
Cratr
> 0.12 Sec
24.0 Volt
90 IPM
Set Desired Time
Parameter
Select
Increase/
Decrease

11-7. Setting Retract Sequence Display

> Rtrct
150 IPM
0.00 Sec
Parameter
Select
OM-196 188 Page 98
1
Cratr
0.12 Sec
> 18.0 Volt
90 IPM
Set Desired
Voltage
Increase/
Decrease
Proceed to next Section.
1
Rtrct
> 150 IPM
0.00 Sec
Set Desired Speed
Increase/
Decrease
> Rtrct
Proceed to next Section.
Cratr
0.12 Sec
18.0 Volt
> 200 IPM
Parameter
Set Desired Wire
Select
Feed Speed
Increase/
Decrease
> Cratr
0.12 Sec
18.0 Volt
200 IPM
Parameter
Select
Increase
Rtrct
120 IPM
> 0.00 Sec
Parameter
Set Desired Time
Select
Increase/
Decrease
130 IPM
0.12 Sec
Parameter
Select
Increase
1
Crater Parameters Display
Parameter ranges are as follows:
Seconds, 0-2.50 Sec. If value set is
zero (0), there is no Crater
sequence.
Volts, 10.0-38.0 Volts.
Wire Feed Speed, 50 to 780 inches
per minute, IPM.
Go to Section 11-7.
1
Retract Parameter Display
Parameter range is as follows:
Seconds, 0-1.00 seconds. If value
set is zero (0), there is no Burnback
sequence.
IPM 50-780 (1.3-19.8 mpm). Speed
is program dependent.
Go to Section 11-8.