Information regarding design and operation
Installation in several rows, connection from the left or right
A
A Collector temperature sensor
Horizontal installation on a pitched roof
1 collector array
A
18
With this type of connection, the "Relay kick" function on the
Vitosolic 200 must be enabled.
A Collector temperature sensor
For this type of installation, ensure the following minimum flow rates
in the collector array (section):
2
2
4 m
35 l/(hm
)
2
2
5 m
30 l/(hm
)
≥6 m
2
25 l/(hm
2
)
2
2
3 m
45 l/(hm
)
2
2
< 2 m
65 l/(hm
)
18.5 Installation examples Vitosol 200-T, type SP2A
Take ventilation into consideration when designing the collector arrays
(see chapter "Ventilation" on page 151).
VIESMANN
142
(cont.)
2 or more collector arrays (≥ 4 m
A
With this type of connection, the "Relay kick" function on the
Vitosolic 200 must be enabled.
A Collector temperature sensor
2
)
VITOSOL