Vitosol 300-F, type SV3 and SH3

6.2 Specification

For locations between 100 and 1000 m from the coast we recom-
mend the Vitosol 200-F, type SV2D.
In close proximity to the coast (up to 100 m), always install the
Vitosol 200-F, type SV2D.
Vitosol 200-F, type SV2D has a special absorber coating that allows
these collectors to be used in coastal regions.
Type
Gross area
(required when applying for subsidies)
Absorber area
Aperture area
Installation position (see following diagram)
Clearance between collectors
Dimensions
Width
Height
Depth
The following values apply to the absorber area:
– Optical efficiency
– Heat loss factor k
1
– Heat loss factor k
2
Thermal capacity
Weight
Liquid content
(heat transfer medium)
Permiss. operating pressure
(see chapter "Solar expansion vessel")
Max. stagnation temperature
Steam output
– Favourable installation position
– Unfavourable installation position
Connection
B
C
VITOSOL
(cont.)
Note
Viessmann accepts no liability if type SV3C/SH3C is used in these
regions.
m
2
2
m
m
2
mm
mm
mm
mm
%
2
W/(m
· K)
2
W/(m
· K
2
kJ/(m
· K)
kg
litres
bar/MPa
°C
W/m
2
W/m
2
Ø mm
A
E
D
SV3C
A (above roof and roof
integration), C, D
2
)
SH3C
2.51
2.32
2.33
B (above roof and roof in-
tegration), C, D, E
21
1056
2380
2380
1056
90
90
86.3
3.143
0.023
5.0
5.0
41
1.83
2.48
6/0.6
206
60
100
22
VIESMANN
27
6