Solar control units
(cont.)

10.2 Vitosolic 100, type SD1, part no. Z007 387

Specification

Construction
The control unit comprises:
■ PCB
■ LCD
■ Selector keys
■ Connection terminals
– Sensors
– Solar circuit pump
– KM BUS
– Power supply (on-site ON/OFF switch)
■ PWM output for controlling the solar circuit pump
■ Relay for actuating pumps and valves
The standard delivery includes collector temperature sensor and cyl-
inder temperature sensor.
Collector temperature sensor
For connection inside the appliance.
On-site extension of the connecting lead:
■ 2-core lead, length up to 60 m with a cross-section of 1.5 mm
per)
■ Never route this lead immediately next to 230/400 V cables
Lead length
IP rating
Sensor type
Permissible ambient temperature
– during operation
– during storage and transport
Cylinder temperature sensor
For connection inside the appliance.
On-site extension of the connecting lead:
■ 2-core lead, length up to 60 m with a cross-section of 1.5 mm
per)
■ Never route this lead immediately next to 230/400 V cables
Lead length
IP rating
Sensor type
Permissible ambient temperature
– during operation
– during storage and transport
For systems with Viessmann DHW cylinders, the cylinder temperature
sensor is installed in the threaded elbow (see chapter "Specification"
of the relevant DHW cylinder and chapter "Installation accessories")
in the heating water return.

Delivered condition

■ Vitosolic 100, type SD1
■ Cylinder temperature sensor
■ Collector temperature sensor

Tested quality

CE designation according to current EC Directives
VITOSOL
Functions
■ Switching the solar circuit pump for DHW and/or swimming pool
■ Electronic limiter for the temperature in the DHW cylinder (safety
■ Collector safety shutdown
Information regarding auxiliary function for DHW heating and
suppression of reheating by the boiler
Systems with Vitotronic control units with KM BUS offer optional sup-
pression of reheating by the boiler and auxiliary function for DHW
heating.
Systems with other Viessmann control units only offer optional sup-
pression of reheating by the boiler.
For further functions, see chapter "Functions".
Specification
2
(cop-
2.5 m
IP 32 to EN 60529; ensure
through design/installation
Viessmann NTC 20 kΩ at
25 °C
−20 to +200 °C
−20 to +70 °C
Rated voltage
Rated frequency
Rated current
2
(cop-
Power consumption
Safety category
IP rating
3.75 m
IP 32 to EN 60529; ensure
Function
through design/installation
Permiss. ambient temperature
Viessmann NTC 10 kΩ at
– during operation
25 °C
0 to +90 °C
– during storage and transport
−20 to +70 °C
Rated relay output breaking capaci-
ty
– Semi-conductor relay 1
– Relay 2
– Total
heating
shutdown at 90 °C)
170
47
230 V ~
50 Hz
4 A
2 W
(in standby mode 0.7 W)
II
IP 20 to EN 60529; ensure
through design/installation
Type 1B to EN 60730-1
0 to +40 °C for use in the living
space or boiler room (standard
ambient conditions)
−20 to +65 °C
0.8 A
4(2) A, 230 V~
max. 4 A
VIESMANN
10
39