Design information regarding installation on pitched roofs — above roof installation
Mounting rails are fitted directly to the mounting brackets.
A
B
15
A Vitosol-F, for vertical and horizontal installation
B Vitosol-T, for vertical installation
C Vitosol-T, for horizontal installation
Design information regarding installation on pitched roofs — roof integration

15.1 Roof integration with flashing frame

Observe the information on securing collectors on page 111.
The Vitosol 200-F flat-plate collector, type 5DIA is designed for this
type of installation.
Required roof area: a = 3000 mm, b = 4000 mm
15.2 Roof integration with flashing frame and side flashing
Observe the information on securing collectors on page 111.
Vitosol 200-F and 300-F flat-plate collectors, type SH and SV are
designed for this type of installation.
Note
Type SH is not designed for the installation of only one collector.

Installation versions

Standard version A
For tiled roofs
VIESMANN
124
C
This fixing system is only offered for roof tiled roofs.
If several collectors are installed above each other, maintain a clear-
ance of 2 to 3 rows of tiles between the collector rows.
A
E
A Collector
B Flashing frame
C Timber
E Aluminium apron (water drainage)
This roof integration is designed for roof covers with roof tiles, plain
tiles and slate:
■ For roof pitches from 15 to 20° and 20 to 65°.
■ One or two rows of collectors.
More than two rows above one another on request.
Design version B
For covers with plain tiles and slate
(cont.)