Immersion Temperature Sensor; Collector Temperature Sensor; Stainless Steel Sensor Well; Heat Meter - Viessmann VITOSOL 100-F SV Technical Manual

Table of Contents

Advertisement

Solar control units
(cont.)

Immersion temperature sensor

Part no. 7426 247
For installation in the DHW cylinder, heating water buffer cylinder,
combi cylinder.
■ For DHW circulation diversion in systems with 2 DHW cylinders.
■ for return changeover between the boiler and the heating water buf-
fer cylinder
■ for heating additional consumers.
■ For a heat statement (return temperature is captured).
On-site extension of the connecting lead:
■ 2-core lead, length max. 60 m with a cross-section of 1.5 mm
per)
■ Never route this lead immediately next to 230/400 V cables

Collector temperature sensor

Part no. 7831 913
Immersion temperature sensor for installation in the solar collector.
■ For systems with two collector arrays.
■ For a heat statement (flow temperature is captured).
On-site extension of the connecting lead:
■ 2-core lead, length max. 60 m with a cross-section of 1.5 mm
per).
■ Never route this lead immediately next to 230/400 V cables.

Stainless steel sensor well

Part no. 7819 693
S W

Heat meter

Components:
■ 2 sensor wells
■ Flow meter with connection fitting to capture the flow rate of
water:glycol mixtures (Viessmann heat transfer medium "Tyfo-
cor LS" with 45 % glycol volume ratio):
Heat meter
06 Part no. 7418 206
15 Part no. 7418 207
25 Part no. 7418 208
a
VITOSOL
2
(cop-
2
(cop-
2 4
Specification
Lead length
IP rating
Sensor type
Permissible ambient temperature
– during operation
– during storage and transport
Specification
Lead length
IP rating
Sensor type
Permissible ambient temperature
– during operation
– during storage and transport
For temperature controllers and temperature sensors.
Part of the standard delivery of the Viessmann DHW cylinders.
35 Part no. 7418 209
60 Part no. 7418 210
260
3.8 m
IP 32 to EN 60529; ensure
through design/installation
Viessmann NTC 10 kΩ, at
25 °C
0 to +90°C
−20 to +70 °C
2.5 m
IP 32 to EN 60529; ensure
through design/installation
Viessmann NTC 20 kΩ, at
25 °C
−20 to +200 °C
−20 to +70 °C