Design information regarding installation on pitched roofs — roof integration
Number and length of the timbers in the packs
Type SV, single row (if installing two rows, double the relevant number)
15
Number of collec-
tors
Length of timber 40 x
120 mm
1500 mm
2600 mm
Length of timber 40 x
60 mm
1500 mm
2600 mm
Type SH
All the timbers are 3000 mm long.
■ Single row installation:
Two timbers per collector of each version
■ Double row installation:
Double the relevant number.

Required roof area

Standard version A
Type
SV
Collector instal-
Single
lation
row
a in mm
b in mm
1650 + 1080 for each
additional collector
Design version B
Type
SV
Collector instal-
Single
lation
row
a in mm
b in mm
1650 + 1080 for each
additional collector

Routing solar lines through the roof

For routing the solar lines through the roof, Viessmann offers special
side panels C (side panels with EPDM entries). These vary depend-
ing on the version of hydraulic connections to be used (see the fol-
lowing diagrams). Specify the version when ordering.
VIESMANN
126
1
2
3
Number of timbers
2
2
2
2
5
5
5
5
SH
Double
Single
row
row
2980
5380
1650
5250 + 2400 for each
additional collector
SH
Double
Single
row
row
3390
5790
1990
5360 + 2400 for each
additional collector
4
5
6
2
4
4
6
5
10
10
15
G
D Collector with side flashing
E Flashing frame
F Timber 120 x 40 mm
Double
G Top and bottom flashing from the design version B (see
row
page 124)
2730
Double
row
3070
7
8
9
2
2
6
8
8
5
5
15
20
20
G
E
D
F
(cont.)
10
12
10
12
25
30
VITOSOL