Concept Of Parts Life; Life Value Of Consumables And Parts - Konica Minolta bizhub C200 Service Manual

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

Field Service Ver. 1.0 Jun. 2008
3.3

Concept of parts life

3.3.1

Life value of consumables and parts

• The life counter value of each materials and parts is available from [Service Mode] →
[Counter] → [Life].
• Life specification value means an actual life terminated when prints are made under the
conditions as defined in the next section, "Conditions for life specifications values."
The actual life may vary greatly depending on how the machine has been used and other
factors.
The waste toner full sensor detects the amount of toner
Waste toner
accumulated in the waste toner box and sends a signal that
box
determines the end of the waste toner box life.
Comparing the number of printed pages *6 with the number
of printed pages calculated based on how long the transfer
belt has run, the machine detects the end of unit life when
Transfer belt
either of them reaches the set value shown on the right.
unit
(However, to detect whether the unit reaches the max. life
value, the machine uses only the number of printed pages
calculated based on how long the transfer belt has run.)
Comparing the PC drum rotation time with the PC drum
Imaging unit
rotation time calculated based on the number of printed
C,M,Y
pages *6, the machine detects the end of unit life when
either of them reaches the set value shown in the table
below.
Imaging unit
K
* The PC drum rotation is calculated based on the distance
the PC drum has run.
<Imaging unit life value *4>
Y,M,C
K
*1: A waste toner full condition is detected with detecting the actual waste toner emissions.
*2: Once the toner-full is detected, it has to be replaced with the new waste toner box in
order to reset.
*3: The initiation of any new print cycle is inhibited when reaching the max. life value.
*4: The mark "M" is indicated the value of the number of distance through which the PC
drum has run translated to a corresponding value of the number of hours and the value.
*5: "Normal" and "Long" are the settings provided in [Service Mode] → [System Input] →
[FWD] → [IU Life Setting].
Description
Life value (Specification value)
Normal *5
Long *5
7,042 M
10,563 M
6,947 M
10,421 M
3. Periodical check
Life value
Max. life
(Specifica-
value
tion value)
50,000 *1,2
120,000
150,000 *3
See the imaging unit life
values in the table below.
Max. life value
Normal *5
Long *5
7,355 M
11,033 M
7,178 M
10,767 M
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents