Field Service Ver. 1.0 Jun. 2008
7.2

Solution

7.2.1

C0001: LCT communication error

PC control board (PCCB)
Step
Turn OFF the main power switch, wait for
1
10 sec. or more, and turn ON the main
power switch.
2
PCCB replacement
7.2.2

C0209: LCT elevator motor failure

Elevator motor (M5)
Elevator motor pulse sensor (PS10)
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of motor for proper
2
drive coupling, and correct as necessary.
3
PS10 I/O check, sensor check
4
M5 operation check
5
REYB replacement
6
PCCB replacement
Relevant electrical parts
Action
Relevant electrical parts
Action
WIRING DIAGRAM
Control signal
Relay board (REYB)
PC control board (PCCB)
WIRING DIAGRAM
Control signal
REYB PJ2<A>-5 (ON)
REYB PJ2<B>-6 to 7
7. Trouble code
Location
(Electrical
components)
Location
(Electrical
components)
PC-405 K-5
PC-405 K-7
35