8. Soft Switch
MODE
Bit:
777
Bit
Feature
7
Interval between PIX and
post command
6
5
4
3
2
1
0
MODE
Bit:
804
Bit
7
Restrict SF/SSF communica-
tion (TX).
6
Restrict SF/SSF communica-
tion (RX from other com-
pany's system).
4
Destination machine confir-
mation transmission. <*>
84
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
0 1 1 1
Logic
0
Bit 7-0:
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
0 1 0 0
Feature
0
No
No
Not con-
firm
Field Service Ver. 1.0 Jun. 2008
HEX:07
1
00000000 Not available
00000001 45 msec
|
00000111 75 msec
|
11111111 1315 msec
HEX: 04
Logic
1
Yes
Enables/Disables TTC high resolu-
tion transmission and SF/SSF trans-
mission function.
When this feature is disabled, the
calling machine sends
- DCS stating that it does not provide
SF in response to DIS from called
terminal in the outside network, or
- NSS stating that it does not provide
SF in response to NSF from called
terminal in the internal company
network.
Yes
Enables/Disables TTC high resolu-
tion reception.
When this feature is disabled, the
called machine sends
- 32-bit DIS stating that it does not
support SF, or
- NSF stating that it supports SF.
(This makes SF communication
possible between the calling party
in the internal company network.)
Confirm
Set whether the machine is to exe-
cute destination machine confirma-
tion transmission if a destination
machine confirmation transmission-
use special character string is not
included in the dialed number.
Description