Proflame Ii Remote Control Operating Instructions - Regency City CV50E DIRECT VENT Owners & Installation Manual

Table of Contents

Advertisement

owner's information

Proflame II Remote Control Operating Instructions

The Proflame Transmitter 2 is an integrated part of the Proflame
2 System, which consists of these elements:
» Proflame 2 Transmitter, in conjunction with
» Integrated Fireplaces Control (Proflame 2 IFC)
The Proflame 2 Transmitter controls the following hearth appliance
functions:
1. Main burner on/off.
2. Main burner flame modulation (6 levels).
3. Choice of standing or intermittent pilot (CPI/IPI) (non power vent
only).
4. Thermostat and smart thermostat functions.
5. Accent light modulation (6 levels).
6. Split flow valve (not available).
7. On/Off relay.
8. Comfort fan speed modulation (6 levels) (not available).
The Proflame Transmitter uses a streamlined design with a simple button
layout and informative LCD display (fig. 1). A mode key scrolls between
the features and a thermostat key is used to turn on/off or scroll through
thermostat functions (fig. 1 & 2). There is also a key lock feature (fig. 22).
Figure 1: Transmitter LCD Display
On/off key
Back lit LCD display
Figure 2: Proflame Transmitter
TECHNICAL DATA
REMOTE CONTROL
Supply voltage
Ambient temperature rat-
ings
Typical operative distance
in free air
Radio frequency
16
| City Series CV50E
Thermostat Key
Up/Down Arrow Key
Mode Key
4.5V (three 1.5V AAA batteries)
0 - 50
C (32 - 122
F)
o
o
12 m (39 ft)
315 MHZ (FCC version)
The transmitter and IFC are radio frequency devices.
• Turn OFF the main gas supply of the appliance
prior to installation or maintenance of the IFC, and
removing or reinserting the batteries.
• In case of remote control malfunction, turn off the
IFC device using the ON/OFF main switch.
• For installation / maintenance, switch off the IFC
device removing main power supply plug.
Non-Power Vent Model: Install the 4 AA batteries during power out-
ages to run the main burner. However, the lights will not operate.
Power Vent Model: This appliance will not operate if 120 volt power
is lost within the home.
This appliance requires coding/pairing of the remote control and IFC
(Integrated Fireplace Control).
Pairing the remote control to remote receiver/
battery
holder (if required)
Power the receiver and press the PRG button located on its top right
corner - see the receiver instruction marked (*). The receiver will beep
three times when ready to synchronize with a transmitter. Install three
AAA batteries in the battery bay, at the base of the transmitter (fig. 3).
Press the ON button. The receiver's command is accepted and sets to
the particular code of that transmitter. The system is now initialized.
(*) The receiver may be independent or integral to the IFC hearth appli-
ance control module. The receiver instruction may not be independent
when part of the IFC.
Figure 3: Battery compartment
See instructions in this manual.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cv50e-ngCv50e-lpCity seriesCv50e

Table of Contents