Sign In
Upload
Manuals
Brands
wtw Manuals
Measuring Instruments
MultiLab P5
wtw MultiLab P5 Manuals
Manuals and User Guides for wtw MultiLab P5. We have
1
wtw MultiLab P5 manual available for free PDF download: Operation Manual
wtw MultiLab P5 Operation Manual (251 pages)
Multiparameter Instrument for the total water and wastewater analysis
Brand:
wtw
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Safety Guidelines
3
Table of Contents
5
Contents List
5
Recommended Basic Equipment
13
Explanation of Symbols
17
Instrument View
18
Front View
18
Rear View
19
Connections
20
Ph Electrodes
20
Conductivity Cell
23
Oxygen Probe
23
Explanation of Control Elements
24
Display (Examples of Standard Displays)
24
Abbreviations in the Display
25
Key Operation
26
Selector Switch
27
Cuvette Compartment and Cuvettes
29
Minimum Cuvette Filling
30
Positioning of Cuvettes in the Cuvette Compartment
30
Putting into Operation
31
Mains Power Supply
31
Accumulator Charging
32
Photometrical Measurements
33
Measurement
33
Serial Measurements
33
Repeat Measurement
34
Select Other Methods
34
Photometry - Additional Functions
36
Selection of Indication Form and Dimension
36
Indication of Measuring Range
37
Entering of Lot Factors
39
Selection of Sample Volume (WTW)
42
Entering of the Dilution (MERCK)
44
Switch on Reaction Time
46
Start a Reaction Time
46
Several Reaction Times for a Procedure
48
Absorbance Measurement
51
Absorbance Measurement against a Reference Value
52
Sample Blank Value Correction
54
Ph Measurement
57
Calibration with Standard Buffer Solutions: "Autocaltec
57
Ph Measurement with Autoread (AR)
59
Termination of Measurement with Autoread (Calibration or Measurement)
60
Operation Without Temperature Probe
61
Calibration Without Temperature Probe
61
Ph Measurement Without Temperature Probe
62
Temperature Compensation
63
Further Calibration Functions
64
Summary of the Calibration Functions
64
Autocal (DIN/NIST Buffer Solutions)
64
One and Two Point Calibration Concal with Two Freely Selectable Buffer Ph Values
67
Additional Functions
69
Switching On/Off the Drift Control AR (Autoread)
69
Resolution of the Ph Measurement
70
Reading the Calibration Data
71
MV Measurement
73
Absolute MV Measurement
73
Relative MV Measurement against Offset Voltage Without Temperature Compensation
74
Relative Meas. against Ag/Agcl-Reference Electrode with Temperature Compensation
76
High Resolution MV Measurement
77
Ammonium Measurement
78
Calibration of the Ammonium Electrode
78
Ammonium Measurement
81
Additional Functions
82
Adjustment of Indication Form
82
Reading of Calibration Data
83
Calibration
85
Fluoride Measurement
88
Additional Functions
89
Reading of the Calibration Data
89
Ionselective Measurement
91
Calibration
91
Any Ionselective Measurement
93
Additional Functions
94
Reading of the Calibration Data
94
Conductivity Measurement
97
Connectable Measuring Cells
97
Preparation
98
Measurement
99
Setting of Cell Constant C and Measuring Range
100
Determination of Cell Constant C: "C Cal
102
Setting of the Temperature Function TC
104
Determination of the Coefficient for a Linear Temperature Function: "TC Cal
105
Selection of Reference Temperature Tref
108
Salinity Measurement
109
Further Information on Conductivity Measurement
110
Oxygen Measurement
111
Calibration with Oxical ® -SL or Oxical ® -P
111
Measurement of Oxygen Concentration in Water
112
Measurement of Oxygen Concentration Without Autoread
113
Other Calibration Procedures and Corrections
114
H 2 O-Cal: Calibration in Air Saturated Water
114
O 2 Reference: Calibration against a Known (Titrated) Concentration Value
115
Salinity Correction (no Calibration Procedure)
116
Additional Functions
118
Switching Autoread on and off
118
Dimension Change and Resolution
119
Reading of Calibration Data
121
Measurement of BOD5 / BSB5
122
BSB 5 Meas. Program Acc. to DIN 38409 Part 51
123
Initial Measurement
124
Final Measurement
130
Evaluation
133
Display of Measured Values
135
Erasure of Measured Values
136
Printing of BSB5 Measurements
137
Determination of Oxygen Consumption Rate
140
Acc. to DIN 38414 Part 6
140
Documentation
142
Characterization of Documentations in the Display
142
Call-Up of Menu "Documentation
143
Printing
145
Time Controlled Printout for Ph, MV, ISE N, ISE F, Conductivity, Salinity and Dissolved Oxygen
149
Printing of Calibration Data (Ph, ISE N, ISE F, ISE, Oxygen)
151
Printing of Results
152
Printing of Results, Function "Ident. Nr." Switched on
153
Storage
155
Time Controlled Storage of Ph, MV, ISE N, ISE F, Conductivity, Salinity and Oxygen
159
Storage of Results
160
Storage of Results, Function "Ident. No" Switched on
162
Printing of Stored Results
163
Printing of List of Methods
163
Erasure of Test Values
165
RS 232 C Interface
166
Pin Connections
166
Commands
167
Print Format of Test Values
175
Data Transmission
175
Input of Own Methods
176
Erasure of Own Method
178
Input of a 12Th Filter
178
Software Multi-ACHAT for Windows
178
Configuration
179
Call-Up of Menu "Configuration
179
Language
180
Date and Time
182
Alter Sequence of Methods
183
User Specific Methods
187
Characteristics
187
Linear Adjustment with 10 Test Values
191
Erasure of Characteristic Data
195
Printing of Characteristic Data
197
Filter 12
199
System Info (Software Status)
202
Reset
203
Maintenance
205
Changing the Lamp
205
Performance of Instrument Zero Adjustment
208
Installation of Filter 12
211
Troubleshooting
213
Technical Data
229
Default Settings
229
Instrument
232
Photometer
235
Ph and MV
236
Ise
237
Conductivity
239
Dissolved Oxygen
241
Test Certificate EMC
242
Method List
245
List of Determinations
245
List of Filter and Method Positions
248
Presentation of Measured Values
251
Advertisement
Advertisement
Related Products
WTW pHotoFlex
WTW pHotoFlex Turb
wtw pH 7110
wtw pH 7310P
wtw pHotoFlex STD
wtw pH 3110
wtw pH/Oxi 340i
wtw pH/Cond 340i
wtw pH 330i
wtw pH 3300i
wtw Categories
Measuring Instruments
Accessories
Laboratory Equipment
Control Unit
Touch terminals
More wtw Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL