Sign In
Upload
Manuals
Brands
Mitsubishi Manuals
Controller
QJ61BT11
Mitsubishi QJ61BT11 Manuals
Manuals and User Guides for Mitsubishi QJ61BT11. We have
1
Mitsubishi QJ61BT11 manual available for free PDF download: User Manual
Mitsubishi QJ61BT11 User Manual (312 pages)
CC-Link System Master/Local Module, Mitsubishi Programmable Logic Controller
Brand:
Mitsubishi
| Category:
Controller
| Size: 3.31 MB
Table of Contents
Safety Precautions
2
Revisions
6
Table of Contents
7
Conformation to the EMC Directive and Low Voltage Instruction
12
About the Generic Terms and Abbreviations
13
Product Components
15
1 Overview
16
Features
17
About Added/Changed Functions in Function Version B
26
2 System Configuration
27
Applicable System
28
Applicable Modules and Number of Cpus that Can be Mounted
28
Notes on the System Configuration
30
Equipment List
32
How to Check the Function Version and Serial no
36
About Version 1.10
36
About Use of the QJ61BT11 with the Q00J/Q00/Q01CPU
37
3 Specifications
38
Performance Specifications
38
Maximum Overall Cable Distance (for Ver. 1.00)
39
Maximum Overall Cable Distance (for Ver. 1.10)
41
CC-Link Dedicated Cable
42
4 Functions
43
Function List
43
Basic Functions
45
Communication with the Remote I/O Stations
45
Communication with the Remote Device Stations
47
Communication with the Local Stations
52
Communication with the Intelligent Device Stations
58
Parameter Setting with GX Developer
64
Parameter Setting with Dedicated Instruction
65
Functions for Improving System Reliability
67
Disconnecting Data Link Faulty Stations and Continuing the Data Link with Only Normal Stations (Slave Station Cut-Off Function)
67
Automatically Reconnecting a Disconnected Data Link Faulty Station When It Returns to Normal (Automatic Return Function)
68
Continuing the Data Link When an Error Occurs in the Master Station PLC CPU (Data Link Status Setting When the Master Station PLC CPU Has an Error)
69
Retaining the Device Status of a Data Link Faulty Station
70
(Setting the Status of Input Data from a Data Link Faulty Station)
70
Continuing the Data Link Even When the Master Station Is Faulty (Standby Master Function)
71
Handy Functions
86
Simplifying the Initialization Procedure Registration of Remote Device Stations (Remote Device Station Initialization Procedure Registration Function)
86
Performing High-Speed Processing (Event Issuance for the Interrupt Program)
89
Enabling the Data Link Simply by Powering on (Automatic CC-Link Startup)
92
Communicating with Intelligent Device Stations (Remote Net Mode)
94
Speeding up the Response from Remote I/O Stations (Remote I/O Net Mode)
95
Creating a Program that Contains Modules to be Added in the Future
96
Powering off a Station in Operation Without Error Detection (Error Invalid Station Setting Function)
97
Synchronizing the Link Scan with the Sequence Scan (Scan Synchronous Function)
98
Replacing Modules Without Error Detection (Temporary Error Invalid Station Setting Function)
102
Checking Operations for each Local Station (Data Link Stop/Restart)
103
Station Number Overlap Checking Function
104
Multiple PLC System Support
105
Transient Transmission Functions
106
Performing Transient Transmission (Dedicated Instructions)
106
5 Data Link Processing Time
108
Link Scan Time
108
Transmission Delay Time
111
Master Station Remote I/O Station
111
Master Station Remote Device Station
113
Master Station Local Station
118
Master Station Intelligent Device Station
123
Processing Time for Dedicated Instructions
124
Master Station Local Station
124
Local Station Local Station
127
Master Station Intelligent Device Station
128
Link Refresh Time
129
Master Station/Local Station
129
Station Status at Error Occurrence
131
Status of the Master Station, Standby Master Station (When the Master Station Is Operating) and Remote I/O Station at Error Occurrence
131
Status of the Remote Device Station, Local Station, Standby Master Station (When the Local Station Is Operating) and Intelligent Device Station at Error Occurrence
132
6 Parameter Settings
133
Procedure from Parameter Settings to Data Link Startup
133
CPU Parameter Area and Master Module Parameter Memory
133
Procedure from Parameter Settings to Data Link Startup with GX Developer
134
Procedure from Parameter Settings to Data Link Startup with Dedicated Instruction
134
Parameter Setting Items
135
Example of Parameter Settings with GX Developer
137
Master Station Network Parameter Settings
137
Master Station Automatic Refresh Parameter Settings
142
Local Station Network Parameter Settings
144
Local Station Automatic Refresh Parameter Settings
146
Example of Parameter Setting with Dedicated Instruction
148
7 Procedure before Starting the Data Link
153
Installation
155
Handling Precautions
155
Installation Environment
155
Part Identification Nomenclature and Settings
156
Checking the Module Status (Hardware Test)
159
Connecting the Modules Using the CC-Link Dedicated Cables
161
Wiring Check
162
T-Branch Connection with the CC-Link Dedicated Cable
163
T-Branch System Configuration
163
T-Branch Communication Specifications List
164
Switch Settings
165
Station Number Setting
165
Transmission Rate and Mode Settings
166
Checking the Connection Status (Line Test)
167
8 Programming
171
Precautions on Programming
171
I/O Signals for the PLC CPU
172
I/O Signal List
172
Details of the I/O Signals
174
Buffer Memory
175
Buffer Memory List
175
Buffer Memory Details
177
Link Special Relays and Registers (SB/SW)
187
Link Special Relays (SB)
187
Link Special Registers (SW)
192
9 Communication between the Master Station and Remote I/O Stations
200
Configuring a System
200
Setting the Master Station
201
Setting the Remote I/O Stations
202
Setting the Master Station Parameters
203
Setting the Automatic Refresh Parameters of the Master Station
205
Creating a Program
206
Performing the Data Link
208
Confirming the Operation with the LED Display
208
Confirming the Operation with the Sequence Program
209
10 Communication between the Master Station and Remote Device Stations
210
Configuring a System
210
Setting the Master Station
211
Setting the Remote Device Station
212
Setting the Master Station Parameters
213
Setting the Network Parameters of the Master Station
213
Setting the Automatic Refresh Parameters of the Master Station
215
Initial Setting of the Remote Device Station
216
Setting the Target Station Number
216
Setting the Regist Procedure Registration
216
Validating the Remote Device Station Initial Settings
220
Setting with the Sequence Program (Reference)
221
Creating a Program
222
Performing the Data Link
225
Confirming the Operation with the LED Display
225
Confirming the Operation with the Sequence Program
226
11 Communication between the Master Station and Local Stations
227
Configuring a System
227
Setting the Master and Local Stations
228
Setting the Master Station Parameters
229
Setting the Network Parameters of the Master Station
229
Setting the Automatic Refresh Parameters of the Master Station
231
Setting the Local Station Parameters
232
Setting the Network Parameters of the Local Station
232
Setting the Automatic Refresh Parameters of the Local Station
234
Creating a Program
235
Performing the Data Link
238
Confirming the Operation with the LED Display
238
Confirming the Operation with the Sequence Program
239
13 Troubleshooting
242
Verification Upon Problem Occurrence
242
Troubleshooting Procedures When the "ERR." LED of the Master Station Is Flashing or When Normal Data Cannot be Sent/Received During Data Link
249
Error Codes
251
CC-Link Diagnostics Using the GX Developer
256
Appendix
262
Appendix 1 External Dimensions Diagram
262
Appendix 2 Dedicated Instruction List
263
Appendix 2.1 RIRD Instruction
264
Appendix 2.2 RIWT Instruction
272
Appendix 2.3 RIRCV Instruction
274
Appendix 2.4 RISEND Instruction
279
Appendix 2.6 RITO Instruction
287
Appendix 2.7 RLPASET Instruction
290
Appendix 3 Differences between the New and Previous Models
300
Appendix 4 Precautions When Changing from AJ61QBT11 to QJ61BT11
301
Appendix 5 Precautions When Changing from QJ61BT11 of the Function Version a to QJ61BT11 of the Function Version B
301
Appendix 6 Parameter Setting Checklist
302
Appendix 6.1 Parameter Setting Checklist
302
Appendix 6.2 Station Information Setting Checklist
303
Appendix 6.3 Device Assignment Checklist
305
Advertisement
Advertisement
Related Products
Mitsubishi MELSEC QJ61CL12
Mitsubishi MELSEC QJ71C24N
Mitsubishi MELSEC QJ71C24
Mitsubishi QJ71MT91
Mitsubishi QJ71LP21
Mitsubishi QJ71LP21-25
Mitsubishi QJ71LP21GE
Mitsubishi QJ72LP25G
Mitsubishi QJ71PB92V-U-HW
Mitsubishi QJ71E71-B5 Series
Mitsubishi Categories
Air Conditioner
Controller
Projector
Automobile
Engine
More Mitsubishi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL