Huawei FusionModule 1000 Maintenance Manual (207 pages)
Air-Cooled IT Solution
Brand:
Huawei
| Category:
Data Loggers
| Size: 6.01 MB
Table of Contents
About this Document
3
Table of Contents
5
1000 M Precautions
9
1000 M Preparations
11
Tools
11
Obtaining Technical Documents
12
Container Entry Requirements
14
O&M Personnel Skill Requirements
15
1000 M Description
16
O&M Overview
16
Routine Maintenance
16
Alarm Handling
17
Alarm Handling Flowchart
17
Viewing and Collecting Alarm Information
17
Determining the Faulty Area and Alarm Severity
19
Locating and Rectifying Faults
19
Parts Replacement
20
Emergency Operation
21
Contacting Huawei Technical Support
23
4 Routine Maintenance
24
Paint Repair
24
Routine Maintenance
29
Monthly Maintenance
30
Power Supply and Distribution System
30
Cooling System
32
Monitoring System
35
Fire Extinguishing System (Standard)
37
Fire Extinguishing System (CE)
38
Other Systems
39
Quarterly Maintenance
41
Power Supply and Distribution System
41
Cooling System
42
Monitoring System
46
Fire Extinguishing System (Standard)
47
Fire Extinguishing System (CE)
48
Other Systems
48
Semi-Annual Maintenance
49
Power Supply and Distribution System
49
Cooling System
49
Monitoring System
50
Fire Extinguishing System (Standard)
55
Fire Extinguishing System (CE)
58
Other Systems
61
Annual Maintenance
62
5 Alarms and Faults
65
VESDA Alarm
65
Fire Alarms (Standard)
65
Fire Alarms (CE)
66
Temperature Alarms
66
Humidity Alarms
68
Door Sensor Alarms
69
Access Control Alarms
69
Water Intrusion Alarm
70
Hydrogen Alarm
71
Mains Outage
72
Communication Failure Alarms
72
SPD Alarm
73
PDU8000 MDU Alarms
74
ATS Alarms
75
UPS5000-E Alarms
76
Kw Air-Cooled Precision Air Conditioner Alarms
77
Kw Air-Cooled Precision Air Conditioner Alarms
81
6 Parts Replacement
85
Replacing Power Supply and Distribution System Components
85
Replacing a PD510
85
Replacing the MDU
86
Replacing the SPD in a PDC
88
Replacing a UPS5000-E Battery
89
Replacing a Monitoring Rpdu
90
Replacing a Cabinet Rpdu
91
Replacing Cooling System Components
93
Replacing a Remote T/H Sensor for an Air Conditioner
93
Replacing Air Filters for a 20 Kw Air-Cooled Precision Air Conditioner
94
Replacing Air Filters for a 35 Kw Air-Cooled Precision Air Conditioner
96
Replacing Parts of an Air-Cooled Precision Air Conditioner
98
Replacing a Ventilation Vent Air Filter
99
Replacing a Thermal Insulation Layer
100
Replacing Pipes
101
Replacing the Humidifier Water Refill Pipe for a Precision Air Conditioner
101
Replacing the Condensate Drainpipe of a Precision Air Conditioner
102
Replacing Monitoring System Components
103
Replacing a Polymer T/H Sensor
103
Replacing a Water Sensor (Point Type)
105
Replacing a Water Sensor (Rope Type)
106
Replacing a Door Status Sensor
108
Replacing a GSM Modem
109
Replacing a Hydrogen Collector
111
Replacing a Hydrogen Exhaust Fan
113
Replacing a Camera
115
Replacing a VCN500
117
Replacing a LAN Switch
119
Replacing the ECC500 Collector
121
Replacing an RH2288 Server
123
Replacing Access Control Components
124
Replacing a Card Reader
124
Replacing an Exit Button
126
Replacing an Electronic Lock
127
Replacing an Emergency Door Release Button
129
Replacing a Fingerprint Scanner
131
Replacing an Access Controller
132
Replacing Fire Extinguishing System Devices (Standard)
134
Replacing a Smoke Detector (Standard)
134
Replacing a Heat Detector (Standard)
136
Replacing the Gas Release Indicator (Standard)
138
Replacing an Indoor Fire Alarm Horn/Strobe (Standard)
140
Replacing an External Horn Strobe (Standard)
142
Replacing a Fire Alarm Sounder (Standard)
144
Replacing the Emergency Start/Abort Switch (Standard)
146
Replacing Batteries for the Fire Alarm Control Panel (Standard)
148
Replacing a Fire Cylinder (Standard)
151
Charging Extinguishant
157
Replacing a Fire Alarm Control Panel (Standard)
160
Replacing an Emergency Light (Standard)
162
Replacing Fire Extinguishing System Devices (CE)
163
Replacing a Smoke Detector (CE)
163
Replacing a Heat Detector (CE)
165
Replacing Warning Signs (CE)
166
Replacing an Internal Horn Strobe (CE)
168
Replacing an External Horn Strobe (CE)
170
Replacing a Fire Alarm Bell (CE)
173
Replacing the Extinguishant Abort Button (CE)
174
Replacing Batteries for the Extinguishant Control Panel (CE)
178
Replacing a Fire Cylinder (CE)
179
Replacing the Extinguishant Control Panel (CE)
182
Replacing an Emergency Light (CE)
184
Replacing Batteries for the VESDA Power Box
186
7 Emergency Operations
189
Emergency Operations for Mains Failure
189
Emergency Operations for Circuit Breaker Tripping
190
Overload Emergency Operations
191
Emergency Operations for Battery Electrolyte Leakage
191
Emergency Operations for Overtemperature
192
Emergency Operations for the Management System Communication Failure
192
Emergency Operations for High Hydrogen Density
193
Emergency Operations for Container Door Cannot Open
194
Emergency Operations for Container Door Open
195
Emergency Operations for an Early Fire Alarm
195
Emergency Operations for a Single Fire Alarm (Standard)
196
Emergency Operations for a Double Fire Alarm (Standard)
199
FIRE RELAY Emergency Operations (CE)
201
Emergency Operations for a LOCAL FIRE Alarm (CE)
203
8 Fusionmodule1000 Emergency Exit Guide
205
9 Acronyms and Abbreviations
206
Advertisement
Advertisement
Related Products
Huawei FusionModule 1000B
Huawei FusionModule 1000A40
Huawei SmartLi 100Ah
Huawei FusionModule 1000A20
Huawei TaiShan 100
Huawei TaiShan 100 2280
Huawei TaiShan 100 5280
Huawei MediaPad 10 FHD
Huawei MediaPad 10 Link
Huawei MediaPad 10 LINK+
Huawei Categories
Cell Phone
Network Router
Wireless Router
Modem
Network Hardware
More Huawei Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL