Cooling Performance

14

SPECIFICATIONS

Model
Cooling Performance Data (Cooling Standards: 95°F
DB/75°F WB outdoor, 80°F DB/67°F WB indoor)
Voltage
Cooling Btu (Rated)
Cooling Btu (Min. – Max)
Outdoor Operating
Range (°F)
Power (W)
SEER
EER
Sensible Heat Ratio
Cooling Amps
Heat Pump Performance Data
Heating Btu (Rated @ 47° F)
Heating Btu (@ 17° F)
Heating Btu (Min. – Max.)
Heat Pump Outdoor
Operating Range (°F)*
COP (Rated @ 47° F)
COP (@ 17° F)
HSPF
Heating Power (W)
Heating Amps
Figure 201 (Cooling Performance)
VRP12K / VRP12R
230/208
265
11,500
5,400– 16,000
55 – 115
927
17.4
12.4
0.71
5.3
4.6
11,200
7,700
4,000 – 14,000
0 – 70
3.4
2.2
10.0
1058
5.3
4.7