Manuals and User Guides for Fire-Lite MS-9600UDLSE. We have
1
Fire-Lite MS-9600UDLSE manual available for free PDF download: Manual
Fire-Lite MS-9600UDLSE Manual (184 pages)
Addressable Fire Alarm Control Panel
Brand:
Fire-Lite
| Category:
Control Panel
| Size: 3.07 MB
Table of Contents
Installation Precautions
3
Table of Contents
5
Section 1: Product Description
12
Inventory
12
Features and Options
12
Specifications
14
1: Current Availability
16
Controls and Indicators
16
Circuits
17
Components
18
1: Intelligent Addressable Detectors: Newer Series
19
2: Intelligent Addressable Modules: Newer Series
19
3: 300 Series Intelligent Addressable Devices
19
4: Addressable Device Accessories
19
Optional Modules
20
Accessories
20
1: PS-Tools Programming Utility
20
2: Dress Panel: DP-9692
21
3: TR-CE Trim Ring
21
4: Battery Box
21
5: Battery Charger
21
6: Ecc-50/100
22
7: Ecc-Fft
22
8: W-GATE Wireless Gateway
22
9: ANN-BUS Annunciators/Devices
22
Remote Fire Annunciator
22
ANN-S/PG Serial/Parallel Interface Installation
23
ANN-I/O LED Driver Module
23
ANN-LED Annunciator Module
23
ANN-RLY Annunciator Module
23
10: Legacy ACS Annunciators
23
Getting Started
24
Section 2: Installation
26
Mounting
26
Power
30
1: AC Power and Earth Ground Connection
30
2: Battery Power
30
3: Special Application DC Power Output Connection
31
Relays
31
Notification Appliance Circuits
31
1: Configuring Nacs
32
2: Style y (Class B) NAC Wiring
33
3: Style Z (Class A) NAC Wiring
33
Power-Limited Wiring Requirements
34
Optional Modules and Devices
35
1: DACT-UD2 Installation
36
2: 4XTMF Transmitter Module Installation
39
3: Auxiliary Trouble Input (J16 & J17)
41
4: SLC-2LS Expander Module
41
5: Printer/Pc
42
6: ANN-BUS Annunciators/Devices
44
ANN-BUS Wiring
44
ANN-BUS Device Addressing
47
Remote Fire Annunciator
47
ANN-S/PG Serial/Parallel Interface Installation
50
Printer Installation
51
ANN-I/O LED Driver Module
52
ANN-LED Annunciator Module
55
ANN-RLY Annunciator Module
57
7: Automatic Audio Panel Control
59
8: ACS Annunciators
61
Legacy ACM-8RF Relay Control Module
61
Legacy ACM Series Annunciators
61
9: ECC-FFT Firefighter Telephone
62
10: W-GATE Wireless Gateway
62
Section 3: Programming
64
Programming Data Entry
64
User Programming
65
Initial Power-Up
66
Programming Screens Description
66
Programming and Passwords
66
Master Programming Level
67
1=Autoprogram
67
2=Point Program
68
Detector Programming
68
Module Programming
76
MNS Override
87
3=Zone Setup
87
Enable
87
Disable
87
Zone 97, 98 and 99
88
Zones Installed
88
Zones Enabled
89
Zones Disabled
89
Zone Type
89
Zones Available
90
Zone Message
90
4: Loop Setup
90
Loop Selection
90
Loop Protocol
91
5: System Setup
91
Trouble Reminder
92
Banner
92
Time-Date
93
Timers
94
NAC (Notification Appliance Circuit)
96
Relays
99
Canadian Option
100
Waterflow Silenceable
101
MNS Override
101
6: Verify Loops
101
7: History
101
View Events
102
Erase History
102
8: Walktest
102
9: Option Modules
103
Annunciators
104
On Board DACT
116
Printer/Pc
116
10: Password Change
117
11: Clear Program
117
12: Program Check
118
Maintenance Programming Level
119
1: Disable Point
119
2=History
120
3: Program Check
121
4: Walktest
122
5: System
122
6: Zone Setup
123
Zones Installed
124
Zones Enabled
124
Zones Disabled
124
Zone Type
124
Zones Available
125
Zone Message
125
Section 4: Operating Instructions
127
Panel Control Buttons
127
1: Acknowledge/Step
127
2: Alarm Silence
127
3: Drill/Hold 2 Sec
127
4: Reset
127
LED Indicators
127
Normal Operation
128
Trouble Operation
129
Alarm Operation
130
Supervisory Operation
131
Process Monitor Operation
132
Hazard Condition Operation
132
Medical Alert Condition Operation
132
Mass Notification Operation
133
Programmed Zone Operation
133
Disable/Enable Operation
133
Waterflow Circuits Operation
133
Detector Functions
133
Time Functions: Real-Time Clock
134
NAC Operation
134
Synchronized NAC Operation
134
Coded Operation
135
Presignal
135
Positive Alarm Sequence
135
Special System Timers
136
1: Silence Inhibit Timer
136
2: Autosilence Timer
136
3: Trouble Reminder
136
4: Waterflow Retard Timer
137
5: Alarm Verification
137
Walktest
137
Read Status
138
1=System Point
138
3=Power
138
2: Zones
139
4: Trouble Reminder
140
5: Timers
140
6: Nac
140
7: Relays
141
8: Program Check
141
9: History
141
10: Annunciators
142
11: Phone Line
142
12: Central Station
143
13: Service Terminal
143
14: Printer/Pc
143
15: Print
144
16: Time-Date
145
Section 5: Power Supply Calculations
146
Overview
146
Calculating the AC Branch Circuit
146
Calculating the System Current Draw
146
2: How to Use Table 5.3 on Page 148 to Calculate System Current Draw
147
Calculating the Battery Size
149
1: NFPA Battery Requirements
149
2: Selecting and Locating Batteries
149
Appendix A: Software Zones
150
A.1: Correlations
150
Appendix B: Default Programming
158
Appendix C: NFPA Standard-Specific Requirements
159
C.1: Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts
165
C.2: MBT-1 Municipal Box Trip - Silenceable
166
Appendix D: FACP with Keltron
167
Appendix E: Wire Requirements
168
E.1: NAC Wiring
169
Appendix F: HVAC Control
170
F.1: Control Module Operation
170
F.1.1: Hvac Shutdn
170
F.2: Monitor Module Operation
170
F.2.1: Hvac Restart
170
F.2.2: Hvac Ovrride
171
Appendix G: Canadian Applications
172
Index
174
MS-9600LS Series & MS-9600UDLS Series Fire Alarm Control Panels
181
Advertisement
Advertisement
Related Products
Fire-Lite MS-9600E
Fire-Lite MS-9600LS
Fire-Lite MS-9600LSE
Fire-Lite MS-9600UDLS
Fire-Lite MS-9600LSC
Fire-Lite MS-9050UDC
Fire-Lite MS-2410BC
Fire-Lite MS-2E' MS-4E
Fire-Lite MS-9050UDE
Fire-Lite MP-12
Fire-Lite Categories
Control Panel
Security System
Fire Alarms
Smoke Alarm
Control Unit
More Fire-Lite Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL