This addendum replaces the existing Section E in your E-Plex 5000
Cylindrical Installation Instructions.
E. INSTALLING & HANDING THE INSIDE UNIT ASSEMBLY
Note: Installing levers to the unit assemblies before mounting them may
ease initial installation.
E-1
Remove screws and rotate this plate
inside face out to change from left hand
to right hand. There should be an "R" for
"Right Hand" stamped on the inside face.
Reinstall screws.
Inside Housing set up
for RIGHT HAND
R
Inside Housing set
up for LEFT HAND
R
Inside Face of Plate
E-2 Select the LectroBolt (screw with red sleeve) length that corresponds
to the correct door thickness as noted in this chart:
Door Thickness
LectroBolt Size
3
1
1
" to 1
"
8
2
(35 mm to 38 mm)
(60 mm)
5
1
" to 2"
8
(41 mm to 51 mm)
(70 mm)
1
1
2
" to 2
"
8
4
(54 mm to 57 mm)
(76 mm)
E-3 Insert spindle (F) into
the hole (G) as shown
below until it "snaps"
into place. Place the
K
outside trim (K) onto
the door, inserting the
spindle (F) into the
hole in the door (H).
Put the thumbturn (T)
in a vertical position
and place the trim
assembly on the door
so that the spindle (F)
engages the thumbturn.
Ensure the red collar (J) is seated into its mounting hole. Carefully
push the inside housing (L) flush against the door.
E-4 Insert LectroBolt through the red inside
housing hole marked with the lightening
bolt symbol.
For now, only partially tighten the
LectroBolt to keep the red
collars in position.
Then, insert and tighten the other three
mounting bolts.
Finish tightening the LectroBolt to
secure the lock on the door.
Warning: If using a power drill, please be careful not to over-tighten as
this could cause damage to the mounting screws and threads.
Mounting Screws Size
3
1
2
"
2
"
8
2
(64 mm)
3
7
2
"
2
"
4
8
(73 mm)
1
3"
3
"
4
(83 mm)
J
J
G
F
H
LectroBolt
here
LectroBolt
screw
Mounting screws
L
T