Section 2: Framing - Montigo H42DF ST Installation & Maintenance Manual

Indoor residential gas fireplace
Hide thumbs Also See for H42DF ST:
Table of Contents

Advertisement

H*42DF ST Indoor Gas Fireplace

Section 2: Framing

Frame in the enclosure for the unit with framing materials. The framed
1).
opening for the assembled fireplace is 45" wide, x 49½" high x 24"
deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure there is
access to install the gas line when the unit is installed. See Figure 19.
45" (rough opening)
49½"
46½"
Combustible material
Backframe, 2-pieces. Both
Sides Typical. See figure 3.
Figure 2. Framing dimensions, (Both Sides Typical).
Frame the fireplace cavity according to Figure 2.
„ Slide the fireplace into the cavity.
„ Tack four studs (Vertical, "broken line") in place, shown in Fig 3.
„ Secure the fireplace in position by nailing into these cleats.
45"
Figure 3. Securing the fireplace to the framing cleats.
Page 8
Installation
Both walls Typical. May
not be exactly as shown.
Non-Combustible
headers (Supplied).
Figure 4. Combustible Framing for shelves over the fireplace, Top vent.
24"
Figure 5. Non Combustible Framing with alcove above fireplace,
Right side. Combustible Framing above fireplace, Left side, see
figure 2. (Top Vent).
Note: Images are shown without screens for clarity purposes. However,
your fireplace should not be operated without proper installation of
screens.
Combustible material Backframe,
2-pieces. Both Sides Typical
Combustible Header
Non-Combustible Header
Combustible Shelf
PEL Short
90 elbow
50"
Top Vent
Min. 1 "
Combustible
Header
49½"
Flex or Rigid
Insulated Sleeve
CRS101
19"
46½ "
49½"
to 1st combustible
Stud
Ceiling level
Non-Combustible
materials. Alcove
over fireplace.
Non-Combustible
Header
Non-Combustible Nail-
10"
ing Flange, (supplied).
Both sides Typical.
See figure
6.
6"
40½"
Floor
XG0237 - 150204

Advertisement