Montigo H42DF Installation & Maintenance Manual
Montigo H42DF Installation & Maintenance Manual

Montigo H42DF Installation & Maintenance Manual

Indoor residential gas fireplace
Table of Contents

Advertisement

Installation & Maintenance Manual
SCH42
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
TWO PLACE DECIMAL
DATE
CHANGED BY
THREE PLACE DECIMAL
ALL BENDS ARE ASSUMED
Read and understand this manual. Improper installation, adjustment, alteration,
TO BE 90 UNLESS NOTED
-
-
OTHERWISE.
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
XG0148
DANGER
NAME
DATE
Description
PC
12/09/2014
Drawn by
1/32"
.015"
DWG. NO.
Revision / Date
A
.005"
Revision
MATERIAL
Finish
SCALE
CAUTION
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H42DF WITH SCREEN
ASSY
H42DF-W/SCREEN
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
SHEET 1 OF 1
1:12
WEIGHT:
injury, property damage or even death.
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
Blank
Blank
Flammable materials
Explosion risk
Toxic
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Flammable materials
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Explosion risk
Toxic
General Warning
Laser Radiation
Biohazard
Irritant
Slippery floor
Watch your step
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Irritant
Slippery floor
Watch your step
Gas bottles
Watch for
Electricity
Flammable materials
Explosion risk
falling objects
Toxic
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Gas bottles
Watch for
Electricity
Low temperature
Strong magnetic field
falling objects
Optical radiation
General Warning
Laser Radiation
Biohazard
Gas bottles
Watch for
Electricity
Low temperature
Strong magnetic field
falling objects
Optical radiation
Irritant
Slippery floor
Watch your step
Low temperature
Strong magnetic field
Optical radiation
Gas bottles
Watch for
Electricity
falling objects
H42DF HL42DF
HW42DF
Indoor
Residential
Gas Fireplace
WARNING
NOTICE
DANGER
IF YOU SMELL GAS
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Oxidising
Hot surface
Danger of entrapment
Danger of death
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Oxidising
Hot surface
Danger of entrapment
Danger of death
Cutting
High temperatures
Glass hazard
Danger of suffocation
Hot surface
Danger of entrapment
Danger of death
Oxidising
Cutting
High temperatures
Glass hazard
Danger of suffocation
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Cutting
High temperatures
Glass hazard
Danger of suffocation
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Oxidising
Hot surface
Danger of entrapment
Danger of death
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Cutting
High temperatures
Glass hazard
Danger of suffocation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
®
C
US
151123

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H42DF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo H42DF

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects ® Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 XG0148 151123...
  • Page 2: Table Of Contents

    H*42DF Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Instruction Manual Contents Designer River Rocks - Converting from H42DFN* to HR42DFN*: Installing the Designer River Rocks: Safety Alerts Installing the Log set:...
  • Page 3: Safety Alerts

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Section A: Before You Start

    Should it be impossible to meet the venting requirements „ laid out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and „...
  • Page 5: Rating Plate Sample

    H*42DF Indoor Gas Fireplace Installation Section: Rating Plate Sample Figure A: Rating Plate for IPI eletronic ignition Figure B: Rating Plate for standing pilot (SIT) Page 5 XG0148 - 151123...
  • Page 6: Section 1: Installation Overview And Product Dimensions

    H*42DF Indoor Gas Fireplace Installation Section: Section 1: Installation Overview and Product Dimensions proper clearances to air conditioning ducts, electrical wiring and Please review the Installation Checklist on Page 4 for general plumbing. Safety, as well as efficiency of operation, should be information on preparing for a successful installation of your considered when selecting the fireplace location.
  • Page 7: Section 2: Framing

    H*42DF Indoor Gas Fireplace Installation Section: Section 2: Framing Frame in the enclosure for the unit with framing materials. The Fireplace without standard screen (pre-January 2015 manufacturing). framed opening for the assembled fireplace is 42" wide, x 46 1/2" high x 21 5/8" deep, see Figure 2 Top Vent Ceiling level NOTE: When constructing the framed opening, please ensure...
  • Page 8: Section 3: Venting

    Montigo dealer to discuss power venting options. Air Baffle for H42DF* & HR42DF* Only: Air Baffle is shipped open. If you are top venting, the air baffle should be closed fol- NOTES FOR PLANNING VENTING:...
  • Page 9: Clearances

    H*42DF Indoor Gas Fireplace Installation Fireplace Clearances: 5” Inner Flue Collar 8” Outer Flue Collar H*42DF 9" 17 1/2" 1" 1" See Section Flue Gasket 6 Finishing around the Flue Cover Plate fireplace † Note: Clearance from top of fireplace to a ceiling within the fireplace enclosure.
  • Page 10: Installing A Roof Mounted Termination (Pvtk-1)

    H*42DF Indoor Gas Fireplace Installation Section: Section 3-2: Installing a Roof Mounted Termination (PVTK-1) This section applies to installations where the direct vent termi- PVTK1 nation will be roof mounted. Termination 2’ min. Section 3-2-1: Venting Layout Selection of components and details of venting lay out should Support ring adhere to the following guidelines: Support plate...
  • Page 11 H*42DF Indoor Gas Fireplace Installation Section: PVTK1 Termination Support plate 32’ max Support ring 18” Max. Figure 10c. Rear vent, Roof mounted venting (1 = 90° bend). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
  • Page 12: Section 3-3-1: Venting Layout

    If your installation does not fall 42” within the venting graph parameters, acceptable. Notes Wall Mounted Terminations: TOP VENT please contact a local Montigo dealer for Power Venting options. All measurements for vertical or horizontal runs are „ measured from center of the vent pipe.
  • Page 13 H*42DF Indoor Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT 4). Installation of termination from inside structure TERMINATION A Termination with a MOSR Frame is installed from the inside of This section applies to installations where the direct vent termi- the structure.
  • Page 14 H*42DF Indoor Gas Fireplace Installation Section: 120” Max Heat Shield 96”Min. Figure 13c. Top Vented, wall mounted Retracted Multi-elbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 13. Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
  • Page 15 H*42DF Indoor Gas Fireplace Installation 45° Corner Installation. 45° or less Corner Installation. Use an PTO-3 termination and an PFL-1 or PFL-2/PFL-2 (12" or Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT-20 to suit, and attach it to the PEL-45. Slide the fireplace 24"...
  • Page 16 If your installation does not fall 33” within the venting graph parameters, please contact a local Montigo dealer for Power Venting options. Figure 15. Rear Vent Venting Graph for wall mounted terminations. Note: Images are shown without screens for clarity purposes.
  • Page 17: Section 3-3-2: Venting Components

    PEXT - 3 (36" f/m Section) any possible hot spots. PEXT - 4 (48" f/m Section) Montigo recommends the use of a flex section for the final „ PEXT - 6 (72" f/m Section) pipe connected directly to the fireplace offering greater E - Elbows PEL-90MM (m/m 90º...
  • Page 18: Section 3-3-3: Heat Shields

    H*42DF Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. Installing a Wall Mounted RHS8 Heat shield The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 16 and 16a) CANNOT be used. Use the RHS101 where any The RHS8 Heat shield CANNOT be used WITHIN 36"...
  • Page 19: Section 4: Wiring

    H*42DF Indoor Gas Fireplace Installation Section 4: Wiring Models H42DFN-F OPTIONAL BATTERY PACK H42DFL-F 1.5V AA type HL42DFN-F 1.5V AA type SPARK GREEN 1.5V AA type WHITE HL42DFL-F 1.5V AA type BLACK BLACK SENSOR To PPO HR42DFN-F HW42DFN-F TO ON/OFF BLUE WALL SWITCH BLUE...
  • Page 20 H*42DF Indoor Gas Fireplace Installation Section: Installing the remote On/Off Wall Switch The H*42DF* gas valve may be connected to a wall switch. Do NOT connect any external power to the remote switch. The valve will generate its own power on a millivolt circuit or will draw its power from an AC Connection inside the fireplace, depending on the model of the unit.
  • Page 21: Cpi [Continuous Pilot Ignition] / Ipi [Intermittent Pilot Ignition] Jumper Cable Installation (Only Available For Sit Electronic Ignition Systems)

    H*42DF Indoor Gas Fireplace Installation Section: CPI [Continuous Pilot Ignition] / IPI Installing the CPI Jumper Cable [Intermittent Pilot Ignition] Jumper Cable 1). Remove the door and valve blind. Installation (only available for SIT Electronic Ignition Systems) “Why use CPI mode”? CPI means “Continuous Pilot Ignition”...
  • Page 22: Section 5-1: Fuel Conversion

    „ remove a 1/8” N.PT. plug to be fitted with a hose barb. NOTICE Montigo requires a service shut off valve be located in an „ accessible location to isolate the gas supply. Only install gas shut-off valves approved for use by the state, When pressure testing the fireplace, Gas line, and input system follow the appropriate „...
  • Page 23: Section 6: Finishing

    H*42DF Indoor Gas Fireplace Installation Section 6: Finishing Side wall clearances are 3". Combustible surrounds may be installed Finishing Around the Fireplace with 3" clearance to the side of the fireplace as shown in Figure 24. Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 23.
  • Page 24: Section 7: Screen Installation And Removal

    For replacement part order numbers, please refer to section "Replacement Parts:" on page 42. Note: Do not operate fireplace without all screens in place. SCH42 Figure 25a. Screen Door Numbers (Replacement Parts) H42DF WITH SCREEN NAME DATE Description DIMENSIONS ARE IN INCHES...
  • Page 25: Section 8: Installing & Removing The Door

    H*42DF Indoor Gas Fireplace Installation Section 8: Installing & Removing the Door Section: Removing the door: The H*42DF* doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch Step 4: the door buckles and, remove the door. Replace in reverse order. Firmly grasp hand-hold end of Door buckle tool and place the machined...
  • Page 26: Installing The Door

    H*42DF Indoor Gas Fireplace Installation Section: Step 8: Removing the Door: Grasp the Door on either side, usually midway and lift upward, lift the door carefully up and away from the front of the fireplace. See Figure 26g. Place the Door aside in a safe place while maintenance and / or cleaning is being performed.
  • Page 27: Section 9: Installing The Accessories

    Installing the Log set: Step 5. Place the Centre Front log , Figure 27c below, as shown using The H42DF* is supplied with a seven ceramic fibre log logset. the notch cast in the Bottom Rear log as shown in figure 27b Unpack the logs and handle them very carefully.
  • Page 28: Installing Firestones In Natural Gas And Propane Fireplaces

    Installing Firestones in Natural Gas and Propane HR42DFN*: Fireplaces To convert your H42DF fireplace to an HR42DF unit with designer The HL42DF* fireplace is supplied with firestones. Remove the river rocks, follow these instructions: door. Follow the instructions to ensure all parts are removed or replaced as required.
  • Page 29: Installing The Designer River Rocks

    H*42DF Indoor Gas Fireplace Installation Section: Remove the Rock Guard and River Rocks from packaging. Install the new Rock Tray and front cover. Make sure the tray is not sitting on top of the pilot. Rock Tray Front Cover Figure 29f. Completed Placement of Rock Guards. Installing the Designer River Rocks: Figure 29c.
  • Page 30 H*42DF Indoor Gas Fireplace Installation Section: Place the (4) four centre faux rocks "B" on the riser spikes, as Place (18) eighteen faux rocks "D" as shown below. shown in the figure below. Spikes, 2-per rock „ „ „ „ „...
  • Page 31: Installing The Log Set

    H*42DF Indoor Gas Fireplace Installation Section: Installing the Log set: 4. Place the Long front Left log (Log D) as shown in figure 30d. Angle log with knot pointing inward toward centre of firebox. The HW42DF* is supplied with a seven ceramic fibre log logset. Unpack the logs and handle them very carefully.
  • Page 32: Section 10: Start-Up Sequence

    H*42DF Indoor Gas Fireplace Operation Section 10: Start-up Sequence with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. WARNING/ CAUTION: Hot while in operation.
  • Page 33: Sit Proflame 2 Electronic Ignition

    H*42DF Indoor Gas Fireplace Operation Section: SIT Proflame 2 Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 6. Turn fireplace "ON" using wall switch or remote control. 2. Remove the lower Horizontal access panel. 7.
  • Page 34: Honeywell Electronic Ignition

    H*42DF Indoor Gas Fireplace Operation Section: Honeywell Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 8. If the fireplace does not operate, follow the instructions 2. Flip down the lower trims. "To Turn Off Gas To Appliance" and call your service 3.
  • Page 35: Optional Remote Operation

    H*38DF Gas Fireplace Operation Optional Remote Operation The Proflame 2 System consists of the following elements: Blue Back lit LCD display 1. Pilot Assembly 2. Proflame Gas Valve. 3. Proflame 2 Control Module On/Off Key 4. Wiring Harness Thermostat Key Up/Down Arrow Key 5.
  • Page 36: Initializing The System For The First Time

    H*38DF Gas Fireplace Operation Section: Initializing the System for the first time Temperature indication Display 1. Set master override switch to off position. With the system in the "Off" position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on 2.
  • Page 37 H*38DF Gas Fireplace Operation Remote-Flame Control Room Thermostat (Remote Control ....Operation) When you turn on the fireplace it starts on high. The proflame 2 has six (6) flame levels. Each time you press the Down Arrow The Remote Control can operate as a room thermostat. The Key once the flame height will reduce by one step.
  • Page 38: Fan Speed Control

    H*38DF Gas Fireplace Operation Section: Disabling Thermostat Fan Speed Control Some jurisdictions and bedroom installations require the The fireplace is equipped with optional hot air circulating fans. thermostat to be disabled. The speed of the fans can be controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds.
  • Page 39: Low Battery Power Detection

    Note, some jurisdictions do no permit the number of changes to the room thermostat set point, etc. use of continuous pilot system. Check local codes or contact your Montigo dealer. Remote Control When the Remote Control batteries are low, a Battery Icon will With the system in "off"...
  • Page 40: Lighting Instructions

    H*42DF Indoor Gas Fireplace Maintenance Maintenance Section: Lighting Instructions Hi-Lo Burner Adjustment: (SIT Nova 820). See pages 32 to 34. The H*42DF* is equipped with an adjustable burner, allowing you General to raise or lower the flames. To adjust the flames, locate the black Have the fireplace and installation inspected yearly.
  • Page 41: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 41 XG0148 - 151123...
  • Page 42: Replacement Parts

    HL42DF Log Set RLGSH42 NG Gas Valve RGC1006 LP Gas Valve RGC1005 NG Pilot RPA020 LP Pilot RPA021 NG Burner Contact Local Montigo Dealer LP Burner Thermocouple RTC182 Thermopile RPG001 Piezo Ignitor PIEZO Pilot Tubing RPTA03 Door RDTH42 Replacement Screen...
  • Page 43: Appendix A: Termination Locations

    H*42DF Indoor Gas Fireplace Appendix Appendix A: Termination Locations Location Canada* USA** 12 inches 12 inches clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 9 inches clearance to sides or bottom of door or operable windows...
  • Page 44: Appendix B: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 45: Appendix C: State Of Massachusetts

    H*42DF Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Appendix: Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 46 H42DF Residential Gas Fireplace XG0148 - 151123...

This manual is also suitable for:

Hl42dfHw42df

Table of Contents