Montigo H42DF Installation, Operation & Maintenance Manual
Montigo H42DF Installation, Operation & Maintenance Manual

Montigo H42DF Installation, Operation & Maintenance Manual

H42df series gas fireplace

Advertisement

H42DF Series Gas Fireplace
H42DF Shown
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Canadian Heating Products Inc. Langley, BC V4W 4A
XG0148
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
®
C
US
www.montigo.com
H42DF
HL42DF
HR42DF
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Montigo Del Ray Corp. Ferndale, WA 98248
Indoor
Indoor
Indoor
Warning:
Installer: Leave this manual
with the appliance.
Consumer: Leave this
manual for future reference.
012810

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H42DF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo H42DF

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. ® • Consumer: Leave this manual for future reference. Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 XG0148 012810...
  • Page 2: Table Of Contents

    Installation, Your new Montigo gas fireplace will give you years of durable, Operations and Maintenance manual. Pay special attention to all reliable use. Welcome to the Montigo family of gas fireplace cautions, warnings, and Important warnings.
  • Page 3: Introduction

    This manual covers all models and unless otherwise specified, the designation H42DF refers to all variations of the model above. Sections The H42DF is rated for Natural Gas and Liquid Propane at 34,000 Max. which are specific to a particular variation are marked with a BTU/H (9.97) Kilowatts, 25.000 Min. BTU/H Input.
  • Page 4: Installation

    H42DF Series Indoor Gas Fireplace Installation Installing The Fireplace Shell Framing * When sheetrock is The fireplace may be installed in any location that maintains proper clear- not used behind the fireplace, framing ances to air conditioning ducts, electrical wiring and plumbing. Safety, depth may be reduced as well as efficiency of operation, must be considered when selecting by 5/8" M”...
  • Page 5: Installing The Gasline

     Use only certified Montigo vent components. (Use of other parts will void an approved fitting, as required by the applicable installation codes. the Montigo warranty, and may impede the operation of the fireplace.) To access the fireplace gas connection the main burner must be ...
  • Page 6: Installing The Standoffs

    Attach to the faceplate of the termination using four sheet metal Installing Terminations with MSR Frames screws. Installing The Standoffs To avoid elevated mantel temperatures, all H42DF Series gas fireplaces are required to have the supplied standoffs installed. The fireplace is supplied with two standoffs. Bend and install these standoffs on top of the fireplace ensuring that the height of the standoff PTO-3F (5"/8")
  • Page 7 Converting to Top Vent/ Rear Vent H42DF Rear Vent H42DF Top Vent Use the following instructions to convert an H42DF for Top Vent use: Use the following instructions to convert an H42DF for Top Vent use: 1. Install the 5" inner flue cap on the rear flue outlet and secure the 1. Install the " inner flue cap on the top flue outlet and secure the cap in place with five screws, as shown in figure 7a.
  • Page 8: Top Vent Venting Runs

    Top Vent Venting Runs Available Top Vent Components The following venting components are available for the H42DF-Series For the H42DF Top Vent, there are two types of installations: A) Through- Top Vent: The-Wall Installations and B) Vertical (Through-The-Roof) Installations. A) Through-The-Wall Installations 5"...
  • Page 9 H42DF Series Indoor Gas Fireplace Installation RHS8 Heat Shield RHS8 Heat Shield PEL-90F/F Elbow Figure 10. Typical Top Vent installation. If the 90° elbow is installed Figure 12. Extended Installation using a combination of solid and flex directly on the fireplace, for height to the center of the venting.
  • Page 10 H42DF Series Indoor Gas Fireplace Installation B. Vertical (Through-The-Roof) Installations Vertical rise >12' can be reduced (on applicable models).  MEXT/PEXT Vertical Terminations must be installed:  • minimum 2' (two feet) above the highest point where vent passes through the roof.
  • Page 11 RHS8 Heat available. These Power Vents are required for Superior venting, safe Shield operation & years of trouble free operation. The available Montigo Power Vent models are: 1 MIN LDVPV47 (Linear, Interior In-line Power Vent, document, XG0700). EDVPV47 (External Power Vent Module, document, XG0750). Figure 18a. RHS8 Installation. (Install by sliding over vent pipe where EDVRSPV47 (Exterior Vertical Roof mount 4/7 stainless steel Power it passes through the combustible construction.
  • Page 12: Rear Vent Venting Runs

    H42DF Series Indoor Gas Fireplace Installation Rear Vent Venting Runs 2. 45° Corner Installation. The H42DF-Series Rear Vent has three possible installations which do Attach an EEL-45/PEL-45 (45° elbow) directly onto the flue collar. not require vertical lift, all of these installations require that you install Cut the EXT-18/PXT-20 to suit, and attach it to the EEL-45/PEL-45. Slide the fireplace into position and attach to the termination. the RHS101 heat shield.
  • Page 13 18" the horizontal run to the wall flange of the vent termination is 84", 33” this would NOT be an acceptable installation. Figure 23. Multi-elbow installation. For H42DF distance 'H' must be a minimum of 50". The vent run must comply with figure 22b. Power Vent models, EDVPV47 33” LDVPV47, EDVRSPV47, and EDVWSPV47 to be used within the shaded area of graph. (See BELOW for...
  • Page 14: Finishing Around The Fireplace

    This can cause melting, deformation, Wall Switch discoloration or premature failure of T.V. and radio components. Figure. 26. Wiring for the H42DF-I with Honeywell gas control and pilot. Page 14 Part No. XG0148 - 012810...
  • Page 15: Removing And Installing The Door

    Removing the door: Installations in Canada which employ the fans must be electrically The H42DF-Series door is removed in a few simple steps. Follow these grounded in accordance with CSA C22.1 Canadian Electrical Code Steps below to remove the Horizontal access panel, unlatch the door Part 1 and/or Local Codes.
  • Page 16: Installing The Door

    H42DF Series Indoor Gas Fireplace Installation WARNING! Step 5: Do not attempt to clean glass when hot. L42DF-ST Ensure the tool is firmly Do not clean glass with abrasive materials as any glass etching in the lower end of the may cause premature glass failure.
  • Page 17: Installing H42Df Logset

    H42DF Series Indoor Gas Fireplace Installation H42DF Installing the H42DF Log Set the underside of the logs, as shown above, figure 30c insets. Installing the Logs: Step 5. Place the Centre Front log , Figure 30d below, as shown using The H42DF is supplied with a seven ceramic fibre log logset. Unpack...
  • Page 18 H42DF Series Indoor Gas Fireplace Installation HR42DF Installing the HR42DF 5. Place (18) eighteen faux rocks "D" as shown below. Artificial Rocks Installing the Artificial Rocks: The HR42DF is supplied with (37) thirty-seven faux ceramic fibre river   rock. Unpack the rocks and handle them very carefully. Shown Below:      ...
  • Page 19 Figure 32b. Spreading designer beads evenly . The HL42DF fireplace has the option of installing the cultured rocks which mimic real stone. These may be spaced at random, or in a visual pattern of your preference. See the Montigo web site for photo- graphs and ideas. www.montigo.com Figure 32c. Completed glass bead installation.
  • Page 20: Lighting Instructions

    H42DF Series Indoor Gas Fireplace Operation - Model H42DF H42DF with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 21 H42DF Series Indoor Gas Fireplace Operation - Model H(R)42DF-I H42DF-I HR42DF-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 22: Operation

    H42DF Series Indoor Gas Fireplace Operation Page 22 Part No. XG0148 - 012810...
  • Page 23 H42DF Series Indoor Gas Fireplace Operation - Model HL42DF-F HL42DF-F with Proflame SIT Electronic Ignition For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 24: Maintenance

    H42DF Series Indoor Gas Fireplace Operation Maintenance Lighting Instructions General Have the fireplace and installation inspected yearly. The inspection See pages 20 to 23.  must include, but is not limited to, the following: • A visual check of the entire vent system and termination.
  • Page 25: Troubleshooting

    H42DF Series Indoor Gas Fireplace Maintenance Troubleshooting Spare Parts H42DF H42DF-I H42DF HL42DF HR42DF HONEYWELL SV9500 /9600 Gas Valve NG RGC3033 RGC1006 RGC1006 Troublshooting Sequence Gas Valve LP RGC3034 RGC1005 NOTE: Before Troubleshooting, Familiarize Yourself With Pilot NG RPA020 RPA020 RPA020 The Startup And Checkout Procedure.
  • Page 26: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 27: Termination Locations

    H42DF Series Indoor Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public † or balcony [16 inches (41 cm) minimum] property [*7 feet (2.1 m) minimum]...
  • Page 28 H42DF Series Indoor Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows:...
  • Page 29 H42DF Series Indoor Gas Fireplace Notes: Page 29 Part No. XG0148 - 012810...
  • Page 30 XG0148 - 012810 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...

This manual is also suitable for:

Hr42dfHl42df

Table of Contents