Section 8: Installing & Removing the Door
Removing the door:
The H*42DF*-ST doors are removed in a few simple steps. Follow these
instructions below to remove the Horizontal access panel, unlatch the
door buckles and remove the door. Replace in reverse order.
WARNING
When reinstalling door(s), always make sure all door
buckles are properly hooked and fully engaged.
Remove the Horizontal Access Pan
Step 1:
Remove the Horizontal cover
by placing fingers in both finger
holes, then pushing away from
you and lifting out. Place it
aside during maintenance or
cleaning.
Install in reverse order.
Figure 22. Removing and installing the Horizontal Access Panel
Step 2:
Locate the Door Buckles:
Figure 22a. Locate the door buckles. (Both Sides Typical)
Step 3:
Release the Door Buckles
Hand-hold
Figure 22b. Door buckle Tool
XG0237 - 150204
Installation
Finger Holes
Installed Gas
Valve Cove r
Door Latch Slot
Door Latch Hook
Step 4:
Firmly grasp hand-hold
end of Door buckle tool
and place the machined
end in the slot under door
frame. (as shown)
Figure 22c.
Step 5:
Ensure the tool is firmly
el:
in the lower end of the
slot, (as shown), Then pull
toward you (Caution: hold
the tool securely).
Figure 22d.
Step 6:
Pull hard if necessary to
release the spring ten-
sion. (Caution: The latch
springs back with force,
hold the tool securely).
Figure 22e.
Step 7:
Remove the tool from
the latch slot. Ensure the
latches are hanging freely,
the hook end is released
from the bottom of the door.
(Repeat all 4-steps for the
remaining latches).
Figure 22f.