v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 4364, 4365, or 4366 server," on page 15 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
161
Real-time clock battery error.
162
Invalid configuration information or CMOS
random-access memory (RAM) checksum
failure.
163
Real-time clock error. (time of day not set)
164
Memory size has changed.
72
IBM System x3250 Types 4364, 4365, and 4366: Problem Determination and Service Guide
Action
1. Reseat the battery.
2. Clear CMOS, see "System-board switches and
jumpers" on page 7.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program,
select Load Default Settings, and save the
settings.
2. Reseat the following components, one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. Failing device (if the device is a FRU, the
device must be reseated by a trained service
technician only)
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. Failing device (if the device is a FRU, the
device must be replaced by a trained service
technician only)
c. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program,
select Load Default Settings, make sure that the
date and time are correct, and save the settings.
2. Reseat the battery.
3. Clear CMOS, see "System-board switches and
jumpers" on page 7.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program; then,
exit, saving the configuration settings.
2. Reseat the DIMMs.