v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 4364, 4365, or 4366 server," on page 15 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
035-xxx-snn
Failed hard disk drive with ID nn on RAID
adapter in slot s.
035-xxx-099
No adapters were found.
035-xxx-s99
Failed RAID test: s = number of failing
adapter slot
075-xxx-000
Failed power supply test.
089-xxx-0nn
Failed microprocessor test.
201-xxx-00n
Failed memory test.
Note: n = slot number of failing DIMM
100
IBM System x3250 Types 4364, 4365, and 4366: Problem Determination and Service Guide
Action
1. Check the system-error logs and replace any
indicated failing devices.
Note: A FRU must be replaced by a trained
service technician only.
2. Reseat the hard disk drive that has ID nn, that is
connected to the RAID adapter in slot s.
3. Replace the hard disk drive that has ID nn, that is
connected to the RAID adapter in slot s.
If an adapter is installed:
1. Reseat the adapter.
2. Check the adapter cables to make sure that they
are secure.
1. Check the system-error logs and replace any
indicated failing devices.
Note: A FRU must be replaced by a trained
service technician only.
2. Reseat the following components:
a. RAID adapter in slot s
b. Cable for the RAID adapter in slot s
c. Riser card
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. RAID adapter in slot s
b. Cable for the RAID adapter in slot s
c. Riser card
d. (Trained service technician only) System
board
Replace the power supply.
1. Make sure that the BIOS code is at the latest
level.
2. (Trained service technician only) Reseat the
microprocessor.
3. (Trained service technician only) Replace the
microprocessor.
Replace the following components one at a time, in
the order shown, restarting the server each time:
1. DIMM identified by nn
2. (Trained service technician only) System board