IBM System x3250 4364 Problem Determination And Service Manual page 117

Hide thumbs Also See for System x3250 4364:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 4364, 4365, or 4366 server," on page 15 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
035-275-001
Adapter Communication error.
035-276-001
Adapter CPU test error.
035-277-001
Adapter Local RAM test error.
035-278-001
Adapter NVSRAM test error.
035-279-001
Adapter Cache test error.
035-280-001
Adapter Drive test error.
035-281-001
Adapter Drive error.
035-282-001
Adapter Parameters set error.
035-283-001
Adapter Battery error.
035-xxx-cnn
c = ServeRAID channel number, nn = ID of
failing fixed disk drive.
Action
1. Update the RAID controller firmware on the RAID
adapter (see "Updating the firmware" on page
11).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
1. Update the RAID controller firmware on the RAID
adapter (see "Updating the firmware" on page
11).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
1. Update the RAID controller firmware on the RAID
adapter (see "Updating the firmware" on page
11).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
1. Update the RAID controller firmware on the RAID
adapter (see "Updating the firmware" on page
11).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
1. Update the RAID controller firmware on the RAID
adapter (see "Updating the firmware" on page
11).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
Replace the attached drive.
Replace the attached drive.
1. Update the RAID controller firmware on the RAID
adapter (see "Updating the firmware" on page
11).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
Replace the battery module on the RAID adapter.
1. Check the system-error logs and replace any
indicated failing devices.
Note: A FRU must be replaced by a trained
service technician only.
2. Reseat the hard disk drive on channel C, ID nn.
3. Replace the hard disk drive on channel C, ID nn.
99
Chapter 5. Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3250 4365System x32504366

Table of Contents