GROUP SETTING
The VSP-8000 lets you operate multiple devices at the same time. To operate a number of devices as a group, you must first set them
as a group. Up to 15 devices can be set as a group. After making any group setting, be sure to perform a group check and store the
new settings in memory.
(Group setting flowchart)
[1] Assign addresses to each group
[1] Assign addresses to each group
S A N Y O C o n t r o l l e r
1 6 : 2 0 : 1 5
G R : 0 1
M X : - -
V R : - -
G R : 0 3
V R : - -
G R : 0 4
V R : - -
Operating procedure
1. Press the GROUP button while holding down the ENTER
button.
•
Enters the setting mode.
2. Press the MODE button to select the type of device the
address is that will be assigned.
3. Press the + (or – ) button to select the group number.
4. Enter the address number with the numeric keypad.
5. Press the ENTER and store the address number in the group.
•
If the device at the specified address is properly
connected, "Complete" appears. If it is not, "No ADR."
appears.
6. Press the CLEAR button.
Note: When two or more VSP-8000s are connected together,
conflicting group assignments cannot be made with
different units.
[2] Operate the addresses assigned to a
group
CLEAR
+
ENTER
GROUP
S E T
-
MODE
-
C M : - -
-
D R : - -
-
S E T
-
S E T
G R : 0 5
S E T
V R : - -
-
1
2
4
5
7
8
0
ENTER
CLEAR
CLEAR
1 Setting mode
G R : 0 1
S E T
M X : - -
-
2 Device selection
G R : 0 1
S E T
V R : - -
-
3 Group selection
G R : 0 3
S E T
+
V R : - -
-
4 Address entry
3
G R : 0 3
S E T
6
V R : - -
5
9
5 Address
assignment
G R : 0 3
S E T
V R : 0 0 5 C o m p l e t e
G R : 0 3
S E T
V R : - -
-
Checking the address assignment
1. Press the GROUP button.
Assigned addresses (max. of three) are displayed.
•
Press the MODE button to select the device type.
•
If four or more addresses exist within the group, then
scroll with the + (or – ) button.
2. Press the GROUP button.
Return to the setting mode.
38
[3] Delete a group address
Checking the address assignment
G R : 0 1
C H E C K
GROUP
V R : 0 0 1 , 0 0 2 , 0 0 3 ,
- +
G R : 0 1
C H E C K
V R : 0 0 4 , 0 0 6 ,
G R : 0 1
S E T
GROUP
V R : - -
-
Need help?
Do you have a question about the VSP-8000 and is the answer not in the manual?