Manual Operation; Optimal Operation; Cleaning And Maintenance; Cleaning The Air Filter - Kelvinator KSE26CRB User Manual

Hide thumbs Also See for KSE26CRB:
Table of Contents

Advertisement

Parts names
Indoor unit
1. Front panel
2. Panel frame
3. Chassis
4. Air filter
5. Horizontal louver
6. Vertical louver
7. Indicator Lamps
8. Manual control button
9. Remote control
10. Refrigerant pipe
11. Drain hose
Air inlet
1
2 3
5
6
Air outlet
7
8
4
1
0
9
Outdoor unit
12 Connecting cable
13 Refrigerant pipe
14 Stop valve
Air inlet (rear)
Air inlet (side)
12
13
Air outlet
14
NOTE: All the pictures in this manual are for explanation
purpose only. Your air conditioner may be slightly different.
The actual shape shall prevail.
12 using the remote control Kelvinator Air Conditioning

Manual operation

Units are equipped with a switch to run emergency operation
mode. This switch can be used as an emergency switch to
switch the system on and off if the remote control fails to work.
Grasp and lift the front panel up to an angle until it
remains fixed with a clicking sound.
Push the button until the AUTO indicator is lit, the unit
will work in forced AUTO mode (the default setting
temperature is 24 ).
Close the panel firmly to its original position.
caution
Once you push the manual button, the operation mode
is shifted in an order as: AUTO, COOL, OFF.
Push the manual button until the Operation indicator
light flashes rapidly (five times per second), the unit
now is operating in forced COOL mode. This is used for
testing purposes only.
To restore the remote control operation, use the remote
control directly.
Front panel
1
1
Front panel
AUTO/COOL
Manual switch

Optimal operation

AUTO/COOL
Manual switch
To achieve optimal performance, please note the following:
Adjust the air flow direction correctly so that it is not
directed on people.
Adjust the temperature to achieve the highest
comfort level. Do not adjust the unit to excessive
temperature levels.
Close doors and windows on COOL or HEAT modes,
or performance may be reduced.
Use TIMER ON button on the remote control to select a
time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the
efficiency of the air conditioner may be reduced and the
air conditioner may stop running.
Clean the air filter periodically, otherwise cooling or
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed position.

Cleaning and Maintenance

warning
Be sure to stop the air conditioner and disconnect the
power supply for your safety during cleaning of the unit.
Cleaning the indoor unit
1
Use a dry cloth.
2
A cloth dampened with cold water may be used if the
indoor unit is very dirty.
3
The front panel of the indoor unit can be removed and
cleaned with water. Then wipe it with a dry cloth.
caution
Do not use detergent or other chemical products
during cleaning. Further, do not put these products
near the indoor unit.
Do not use benzine, thinner, polishing powder or other
similar solvent to clean the unit.
Household
Drain
Cleaner
No

Cleaning the air filter

NOTE: Supply power must be disconnected before cleaning
the indoor unit.
A clogged air filter reduces the cooling efficiency of this unit.
Please clean the filter every month or more often if necessary.
1
Lift the indoor unit front panel up to an angle until it
stops with a clicking sound.
2
Take hold of the handle of the air filter and lift it up
slightly to take it out from the filter holder, then pull
it downwards.
3
Remove the AIR FILTER from the indoor unit. Clean the
AIR FILTER with a vacuum cleaner or water, then dry it
up in a cool place.
4
Remove the Air Freshening Filter (Optional filter:
Plasma Dust Collector/Silver Ion filter /Bio filter /Vitamin
C filter/ 3M air purifier filter) from its support frame.
(There is slightly difference on installation/removing the
filter, see the pictures marked  and .
Clean the air freshening filter at least once a month,
and replace it every 4-5 months.
Clean it with vacuum cleaner, then dry it in a cool place.
warning
Do not touch the Plasma Dust Collector Filter within 10
minutes after opening the front panel, it may cause an
electric shock.
5
Install the air freshening filter back into position.
6
Insert the upper portion of air filter back into the unit,
taking care that the left and right edges line up correctly
and place filter into position.
Maintenance
If the air conditioner is not going to be used for some period
of time:
1
Let the fans run for 3~4 hours to allow the device to
completely dry out.
2
Switch off the device and pull the power plug. Remove
the batteries from the remote control.
3
The outdoor unit requires periodic maintenance and
cleaning. Do not attempt to do this yourself.
Contact your dealer or servicer.
Checks before operation
Check that the wiring is not broken off or disconnected.
Household
Check that the air filter is installed.
Drain
Cleaner
No
Check if the air outlet or inlet is blocked after the air
conditioner has not been used for a long time.
2
2
Kelvinator Air Conditioning cleaning and maintenance 13
Filter Handle
Filter Handle
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents