Kelvinator KSE62HRA Installation Manual

Kelvinator KSE62HRA Installation Manual

Split system

Advertisement

ISSUE No.: 6
DATE: 01/07/07
P/No.: 2020323C0574

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KSE62HRA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kelvinator KSE62HRA

  • Page 1 ISSUE No.: 6 DATE: 01/07/07 P/No.: 2020323C0574...
  • Page 2 Take care not to catch fingers on the fan when adjusting vertical louvres.
  • Page 3 SAFETY PRECAUTIONS...
  • Page 7 / 1 4 9.53mm 6.35mm / 1 4 12.7mm 6.35mm / 1 4 12.7mm 6.35mm 16.0mm 9.53mm 16.0mm 9.53mm (7,000Btu/h and 9,000Btu/h models) 150mm or more to celling Installation plate Indoor unit outline 120mm or more 120mm or more to wall to wall Left regrigerant pipe hole...
  • Page 8 (18,000Btu/h and 21,000Btu/h models) (24,000Btu/h and 30,000Btu/h models) Wall 1. Determine hole positions according to the diagram detailed on pages 6 or 7 as Outdoor applicable. Drill one (1) hole ( 85mm for 7,000, 9,000, 12,000Btu/h models or 115mm for 18,000, 21,000, 24,000 and 30,000Btu/h models) slanting slightly to outdoor side.
  • Page 9 Flare nut Copper tube...
  • Page 10 Connection of pipes - Indoor Tubing retainer...
  • Page 11 Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. Insert the piping, drain hose and the connecting cable into the piping hole.
  • Page 14 Tubing retainer Piping for passage through piping hole Connection cable Drain hose...
  • Page 15 (7,000Btu/h, 9,000Btu/h and 12,000Btu/h Cooling Only Models)
  • Page 16 (7,000Btu/h, 9,000Btu/h and 12,000Btu/h Reverse Cycle Models) (18,000Btu/h and 21,000Btu/h models) (24,000Btu/h and 30,000Btu/h models) For 18,000Btu/h, 21,000Btu/h, 24,000Btu/h and 30,000Btu/h models, a power cord should be installed according to the diagram above.
  • Page 18 CHECKING THE DRAINAGE AND FORMING THE PIPING Tip of drain hose Less than dipped in water 50mm gap...
  • Page 20 Charge hose...
  • Page 21 Pipe Length Air Purge Time required Method (min) Use Vacuum <5m Pump Use Vacuum 5~10m Pressure Pump gauge Open Close Vacuum pump...
  • Page 22 Connection pipe...
  • Page 23 The pressure of the gas side service valve Outside ambient TEMP. 35 C(95 F) 4~5kg/cm (400~490KPa) PUMP DOWN...