Check After Installation And Operation Test; Installation And Maintenance Of Hepa Filter - Kelvinator KSE88CRC Installation Manual

Fixed speed split room air conditioner
Table of Contents

Advertisement

Check after installation and
operation test
Check after installation
Items to be checked
Has the unit been
fixed firmly?
Have you done the
refrigerant leakage test?
Is thermal insulation
sufficient?
Is water drainage
satisfactory?
Is the voltage in accordance
with the rated voltage
marked on the nameplate?
Is the electric wiring or
piping connection installed
correctly and securely?
Has the unit been
securely earthed?
Is the power cord specified?
Is the inlet or outlet
blocked?
Is the length of connection
pipes and refrigerant
capacity recorded?
Operation Test
1
Before Operation Test
a. Do not switch on power before installation is
finished completely.
b. Electric wiring must be connected correctly
and securely.
c. Cut-off valves of the connection pipes should
be opened.
d. All the impurities such as scraps and waste must be
cleared from the unit.
2
Operation Test Method
a. Switch on power and press "ON/OFF" button on the
remote controller to start the operation.
b. Press MODE button to select the COOL, HEAT (Not
available with Cooling Only models), FAN to check
whether the operation is normal or not.
10 Kelvinator Air Conditioning installation instructions
Possible malfunction
The unit may drop, shake
or emit noise.
It may cause insufficient
cooling (heating)
It may cause condensation.
It may cause water leakage.
It may cause electric
malfunction or damage
the unit.
It may cause electric
malfunction or damage
the parts.
It may cause electrical
leakage.
It may cause electric
malfunction or damage
the parts.
It may cause insufficient
cooling (heating)
The refrigerant capacity is
not accurate.
Installation and maintenance of
HEPA filter
Installation of HEPA Filter
1
Lift up the front panel from the two ends of it, as shown
by the arrow direction, and then remove the air filter
2
Attach the HEPA filter onto the air filter
Air filter
3
Install the air filter properly along the arrow direction in
the diagram below, and then close the panel
HEPA filter
Cleaning and Maintenance
Remove the HEPA filter and reinstall it after cleaning
according to the installation instruction. Don't use brush or
hard things to clean the filter. After cleaning, be sure to dry it
in the shade.
Service Life
The general service life for the HEPA filter is about one year
under normal conditions.
Air filter
HEPA filter
Air filter
HEPA filter

Advertisement

Table of Contents
loading

Table of Contents