Testing Grouped Feedback - AMX Novara 1000 Series Operation/Reference Manual

Novara controlpads & keypads
Hide thumbs Also See for Novara 1000 Series:
Table of Contents

Advertisement

AMX Novara DCS1000 Device Configuration Software
For instance Play / Stop / Pause. An LED may be assigned to up to 8 groups.
1.
Clear the program by selecting File > New from the menu bar.
2.
Select Button 1 in the System window (see FIG. 46 on page 34).
3.
Click on Add Panel Feedback to invoke the Select Button Feedback window (FIG. 47 on page 34).
4.
From the Select Action drop-down menu, select On/ Group Off, and click Group1 under Add To Group (as shown
in FIG. 51). Repeat for Buttons 2 to 4.
5.
Select Button 5, click on Add Panel Feedback, select On/ Group Off, and click on Group 2 (FIG. 52).
FIG. 52
Button Feedback - Button 5, On / Group Off, Group 2
Repeat for buttons 6 to 8.
6.
To Save your program, select File > Save from the menu bar.

Testing Grouped Feedback

1.
Download the program to the ControlPad (see the Downloading the Program to the ControlPad section on
page 33).
2.
Press Button 1 - the LED should illuminate.
3.
Now press Button 2, this LED should illuminate, and extinguish Button 1.


36
Only the pressed button of 1 to 4 will stay illuminated.
Likewise only the pressed button of 5 to 8 will stay illuminated.
Novara ControlPads & KeyPads

Advertisement

Table of Contents
loading

This manual is also suitable for:

Novara axlink

Table of Contents