For Hard-Wired Units:
• The white lead must be connected to the neutral conductor of the power source.
CAUTION! Miswiring may result in severe damage to the unit. See Fig. 9.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
E. Front Panel
1) Push the front panel up approximately 1/2" (1.3 cm) until it is disengaged from the
locking collars. See Fig. 10.
2) Rotate the panel up and away from the face of the unit until it stops.
3) Pull the front panel forward until the hinge assembly is in the locked position.
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage
to the unit. The white lead must be
connected to the neutral conductor
of the power source.
See diagram below.
115-120/60/1
JUNCTION BOX
L
BLACK
N
WHITE
3
Pull Forward
2
Rotate
Push Up
1
Fig. 10
12
Fig. 9
4A5263-010
Front Panel
Locking Collar