Cfg_Rtry_Intvl; Cfg_Resync_From_Sip; Cfg_Resync_Action - Panasonic KX-HDV130 Administrator's Manual

Sip phone
Hide thumbs Also See for KX-HDV130:
Table of Contents

Advertisement

5.3.5 Provisioning Settings
Value Range
Default Value
Web User Interface Reference

CFG_RTRY_INTVL

Value Format
Description
Value Range
Default Value

CFG_RESYNC_FROM_SIP

Value Format
Description
Value Range
Default Value
Web User Interface Reference

CFG_RESYNC_ACTION

Value Format
Description
Value Range
190
Administrator Guide
00:00–23:59
Note
If the value for this setting is any valid value other than an empty
string, the unit downloads the configuration files at the fixed
time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are
disabled.
If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Empty string
Time Resync (Page 154)
INTEGER
Specifies the period of time, in minutes, that the unit will retry checking
for an update of the configuration files after a configuration file access
error has occurred.
Note
This setting is available only when "CFG_CYCLIC" is set to "Y".
1–1440
30
STRING
Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Max. 15 characters
check-sync
Header Value for Resync Event (Page 154)
INTEGER
Specifies the value of the action after received resync NOTIFY.
0: Provisioning
1: TR-069 Inform
2: Reboot
Document Version 2015-02