2.4 Configuration File Specifications
"VM_NUMBER_2": for line 2
Note
The number of lines available varies depending on the phone being used, as follows:
KX-HDV130: 1–2
Some parameter values can be specified as "empty" to set the parameter values to empty.
Example:
NTP_ADDR=""
The parameters have no order.
If the same parameter is specified in a configuration file more than once, the value specified first is applied.
All configurable settings can be specified in the configuration file. You can ignore settings that already have
the desired values. Only change parameters as necessary.
Boolean parameters (BOOLEAN) accept all of the following configurations.
"Y": "Y", "y", "Yes", "YES", "yes"
"N": "N", "n", "No", "NO", "no"
Parameter Extensions
You can use parameter extensions to specify parameters as Read-Only or Carrier Default.
Read-Only Specification
When "?R" or "?r" is specified, the phone user interface and Web user interface for the parameter in
question is restricted to Read-Only.
* Restricting the phone user interface to Read-Only
The Read-Only parameter settings menu appears, but an error occurs during registration.
* Restricting the Web user interface to Read-Only
The Read-Only parameter settings menu appears grayed out and nothing can be entered.
Note
Parameters that can be configured from the device and from the Web can be confirmed from
footnotes 1-3 on the parameter names in "5.1 Configuration File Parameter List".
When "?R" or "?r" is not specified, the phone user interface and Web user interface are both readable and
writable.
* Optional specifications for "?R" and "?r" are enabled when the last parameter in question is configured.
Example:
(1) Import XXX?R="111" from the Web as a standard file.
XXX: Read-Only
XXX operational information: 111
(2) Import XXX="222" from the Web as a product file.
XXX : Read/Write
XXX operational information: 222
* When configurations in (1) and (2) are used, the higher priority standard file will be enabled and the value
for XXX in Read-Only mode will be 111.
Carrier Default Specification
When "?!" is specified, applicable parameter values are managed as carrier default values when applied
to operational information.
* Carrier default values are applied once a reset to carrier defaults is executed. Carrier defaults will also
be initialized when a reset to device defaults is executed.
* Once "?!" is specified, the parameter in question will be designated as a carrier default even if said
parameter is configured without "?!". (This setting will remain in place until restored to factory default.)
Specification of Multiple Parameter Extensions
One parameter can be assigned multiple extensions.
52
Administrator Guide
Document Version 2015-02