Poe > Poe Port Settings (Dgs-1210-28P Only) - D-Link DGS-1210/ME User Manual

Metro ethernet switch series
Hide thumbs Also See for DGS-1210/ME:
Table of Contents

Advertisement

4 Configuration
Profile ID (1-50): Specify the profile ID.
Access ID (1-250): Specify the Access ID that will be used to configure the Flow Metering parameters, enter
a value between 1 and 250.
Mode: To be used the corresponding information.
-
Rate: Specify the committed information Rate of the packet. The range is from 64 to 1024000
kbyte.
-
Burst Size: Specify the committed Burst Size of the packet. The range is from 0 to 1016 kbyte.
Rate Exceed: Specifies the action when the packet is in yellow color mode.
-
Drop Packet: Drops the packet.
-
Replace DSCP: Allow user to change the DSCP of the packet.
Click Apply to implement changes made.
PoE > PoE Port Settings (DGS-1210-28P only)
DGS-1210-28P supports Power over Ethernet (PoE) as defined by the IEEE specification. It supplies power
to PD device up to 15.4W for all ports or 30W for port 1~4, meeting IEEE802.3af standards and pre-802.3at
standards.
DGS-1210-28P works with all D-Link 802.3af or 802.3at capable devices. The Switch also works in PoE
mode with all non-802.3af capable D-Link AP, IP Cam and IP phone equipment via the PoE splitter DWL-
P50.
IEEE 802.3at defined that the PSE provides power according to the following classification:
The PoE port table will display the PoE status including, Port Enable, Power Limit, Power (W), Voltage (V),
Current (mA), Classification, Port Status. You can select From Port / To Port to control the PoE functions of
a port. DGS-1210-28P will auto disable the ports if port current is over 375mA in 802.3af mode or 625mA in
pre-802.3at mode.
DGS-1210 series Metro Ethernet Managed Switch User Manual
Class
Usage
Output power limit by PSE
0
Default
15.4W
1
Optional
4.0W
2
Optional
7.0W
3
Optional
15.4W
4
Reserved
30W
Note: The PoE Status information of Power
current, Power Voltage, and Current is the power
usage information of the connected PD; please
"Refresh" to renew the information.
1
1
0
9
0
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents