Table 4-1. Modbus/TCP Mapping Table (Continued)
Catelog
Name
Port Info
Port 26 Flow
Control
Port 27 Flow
Control
Port 28 Flow
Control
Port 29 Flow
Control
Port 30 Flow
Control
Port 31 Flow
Control
Port 32 Flow
Control
Port Descrip-
tion
Port 1
Description
Port 2
Description
Port 3
Description
Port 4
Description
Port 5
Description
Data Type
Inter-
preta-
1 word
16 bits
HEX
1 word
16 bits
HEX
1 word
16 bits
HEX
1 word
16 bits
HEX
1 word
16 bits
HEX
1 word
16 bits
HEX
1 word
16 bits
HEX
20 words
40 chars
ASCII
20 words
40 chars
ASCII
20 words
40 chars
ASCII
20 words
40 chars
ASCII
20 words
40 chars
ASCII
20 words
40 chars
ASCII
Address
Address
Offset
tion
(Hex)
0x1219
34634
0x121A
34635
0x121B
34636
0x121C
34637
0x121D
34638
0x121E
34639
0x121F
34640
0x1400 ~
35121 ~
0x166C
35741
0x1400
35121
0x1414
35141
0x1428
35161
0x143C
35181
0x1450
35201
M
ANAGING
Description
3X
Port Description
Port Description =
"100RX,RJ45."
Word 0 Hi byte = '1'
Word 0 Lo byte = '0'
Word 1Hi byte = '0'
Word 1 Lo byte = 'R'
Word 2 Hi byte = 'X'
Word 2 Lo byte = ','
Word 3 Hi byte = 'R'
Word 3 Lo byte = 'J'
Word 4 Hi byte = '4'
Word 4 Lo byte = '5'
Word 5 Hi byte = '.'
Word 5 Lo byte = '\0'